Digest 174 Quick Page Locator Enter a page number from our paper catalog to go directly to that page in our online catalog. Example: 5 - 3
IEC Style Terminal Blocks AB1RR Spring Clip Terminals, AB1VV and AB1TP Miniature Blocks Refer to Catalog 9080CT9901 Table 24.13: Spring-Clip, AB1RR(continued) Description Maximum Voltage Maximum Currentb Block End Barrier c Color Catalog Number $ Price ea. Std. Pack a Color Catalog Number $ Price ea. Std. Pack a 5 mm (0.20 in.) wide Spring-Clip StyleGrounding BlockTwo TerminalsSolid or Stranded Copper Wire22–12 AWG 600 V 20 A Green / Yellow AB1RRTP235U2 4.80 100 Green AB1RRTPAC242 0.62 10 5 mm (0.20 in.) wide Spring-Clip StyleGrounding BlockFour TerminalsSolid or Stranded Copper Wire22–12 AWG 600 V 20 A Green /Yellow AB1RRTP235U4 5.40 100 Green AB1RRTPAC244 0.62 10 6 mm (0.24 in.) wide Spring-Clip StyleGrounding BlockTwo TerminalsSolid or Stranded Copper Wire 22–10 AWG 600 V 30 A Green /Yellow AB1RRTP435U2 5.00 100 Green AB1RRTPAC242 0.62 10 6 mm (0.24 in.) wide Spring-Clip StyleDiode/Fuseholder BlockSolid or Stranded Copper Wire22–10 AWG 300 V 10 A Gray AB1RRSF435UGR 3.50 100 Gray AB1RRSCAC4 0.62 10 Fuseholder 5x20 (Fuse not included) Depends on fuse or diode used Gray AB1SF520 4.30 100 Not applicable Fuseholder 5x20 + 24 V LED Gray AB1SF520B 13.50 100 Fuseholder 5x20 + 220 V LED Gray AB1SF520M 13.50 100 Holder for Diode (Diode not included) Gray AB1SV1 4.10 100 Holder with 1N4007-1 Diode Gray AB1SV2 10.40 100 Table 24.14: Miniature, AB1VV and AB1TP 5 mm (0.20 in.) wide Miniature Block with Box Lug Solid or Stranded Copper Wire 22–14 AWG Mounts on 15 mm DIN 2 track 300 V 10 A Gray AB1VV215 1.00 100 Gray AB1AC2 0.41 50 Blue AB1VV215BL 1.00 100 Blue 5 mm (0.20 in.) wide Miniature Block with Box Lug Solid or Stranded Copper Wire 22–10 AWG Mounts on 15 mm DIN 2 track 600 V 10 A Gray AB1VV415 1.10 100 Gray AB1AC2 0.41 50 6 mm (0.24 in.) wide Miniature Grounding Block with Box Lug Solid or Stranded Copper Wire 22–14 AWGMounts on 15 mm DIN 2 track 300 V 10 A Green /Yellow AB1TP215 2.90 100 Gray AB1CT215 0.41 50 a Orders must specify the standard package quantity (Std. Pack) or multiples of that quantity. b These maximum current values assume the use of insulated copper conductors with 75oC temperature rating and are calculated based on NEC article 310, Table 310-16. In most cases this value is the maximum ampacity of the wire which has the greatest current carrying capacity. The actual allowable current for a particular application depends on the size, insulation, class and other characteristics of the wire used. The UL ratings are shown. The CSA rating may be higher or lower. Refer to the catalog for CSA ratings. c One end-barrier is required for each assembly of like blocks. FileCCN E164359XCFR2 FileClass LR891506228 01 RoHS Compliant CP5 Discount Schedule Modified 1/17/08 Related Topics For track and accessories, see pages 24-15 and 24-16.
Release Date: 03/31/2007Modification Date: 1/17/2008