Digest 174 Quick Page Locator Enter a page number from our paper catalog to go directly to that page in our online catalog. Example: 5 - 3
NEMA Style Terminal Block Type G Class 9080 / Refer to Catalog 9080CT9601 Table 24.2: Selection Guide Description Maximum Voltage Maximum Current b Blocks End Barriersc Blocksper ft Max. Wire Combinations Type $ Price ea. Std. Pack a Type $ Price ea. Std. Pack a Copper Wire (stranded or solid) Self-Lifting Pressure Wire Connector for #18 to #12 AWG wire. Mounts on standard 9080GH track or 35 mm DIN 3 track. 600 V 40 A GP6 1.70 50 GP6B .68 10 32 1 or 21 or 21 or 21 or 2 #12 #14 #16 #18 Flat Terminal Connector for #22 to #12 AWG wire. Screws are #6-32 x 5/16 in. for ring or spade lugs, 5/16 in. wide maximum. Mounts on standard 9080GH track or 35 mm DIN 3 track. Fingersafe per DIN 57470. 600 V 40 A GA6 1.20 50 GP6B .68 10 32 1 or 2 ConductorsPer Screw#12–22 Circuit Isolating Switchdwith self-lifting pressureconnectorsfor #18 to #10 AWG wire.Mounts on standard 9080GH track or 35 mm DIN 3 track. 600 V 30 A GG6 8.10 10 GF6B 1.00 10 16 1111–41–4 #10 #12 #14 #16 #18 Slip-on Connectors for #22 to #12 AWG wire. Tabs accept 0.250 x 0.032 in. slip-on connectorsMounts on standard 9080GH track or 35 mm DIN 3 track. 600 V 20 A GS6 1.70 10 GF6B 1.00 10 16 1–21–21–21–21–21–2 #12#14#16#18#20#22 Transient Voltage Suppressors fwith box lug connectorsfor #18 to #10 AWG wire. Mounts on standard 9080GH track or 35 mm DIN 3 track. 120 V — GT6 13.80 5 GT6B 1.10 10 24 1111–21–4 #10 #12 #14 #16 #18 Fuse Block for 13/32 in. Dia. x 1-1/2 in. ferrule fuse with self-liftingpressure connectors. Fusepuller is included as standard.Fuses are not included.Mounts on standard 9080GH track or 35 mm DIN 3 track. Fingersafe per DIN 57470. 600 V 30 A GF6 7.80 10 GF6B 1.00 10 16 1111–41–4 #10 #12 #14 #16 #18 Fuse Pullere — — GH63 .21 10 N/A N/A N/A Blown Fuse Indicator/Pullers are neon pilotlights which plug on to thefuse in a standard TypeGF6 fuse block. 120–240 V — GLP3 7.90 10 N/A N/A N/A 277–600 V — GLP6 7.90 10 N/A a Orders must specify the standard package quantity or multiples of that quantity. b These maximum current values assume the use of insulated copper conductors with 75oC temperature rating, and are calculated based on NEC Article 310, Table 310-16. In most cases this value is the maximum ampacity of that wire or combination of wires (as listed in the above table) which has the greatest current carrying capacity. The actual allowable current for a particular application depends on the number, size, insulation class, and other characteristics of the wires used. The lower of the UL and CSA ratings are shown below. c One end-barrier is required for each assembly of like sections. d Not intended to make or break a live circuit. Power must be disconnected from the circuit before operation of the switch. e Fuse puller is supplied as standard with Class 9080 Type GF6 fuse block. The 9080GH63 is a replacement fuse puller. f Modules have RC circuitry for suppressing transient voltage, generated when opening a coil circuit, to approximately 200% of the peak line voltage, when used with 120 V coils. Type GT6 is suitable for use with Square D Class 8501 Type X, K, R and C relays or Square D Type S starters and contactors, Sizes 00-2. Terminal Blocks FileCCN E60616XCFR2 FileClass LR621446228 01 Blown Fuse Indicator FileCCN E63698ZTFR FileClass LR25490184-N-90 Table 24.3: How to Order To Order Specify Catalog Number ▪ Class Number ▪ Type Number Class Type 9080 GP6 CP5 Discount Schedule Modified 1/17/08 Related Topics For Standard or Custom Assemblies page 24-5 For Mounting Track and Accessories page 24-6 For DIN 3 track and end clamps page 24-16
Release Date: 03/31/2007Modification Date: 1/17/2008