NEMA Style Terminal Block

Type G

Class 9080 / Refer to Catalog 9080CT9601

Table 24.2:
Maximum
Voltage
Maximum
Current b
Blocks
per ft
Max. Wire
Combinations
Std. Pack a
Std. Pack a
Self-Lifting Pressure Wire Connector
for #18 to #12 AWG wire. Mounts
on standard 9080GH track or
35 mm DIN 3 track.
1.70
.68
1 or 2
1 or 2
1 or 2
1 or 2
#12
#14
#16
#18
Flat Terminal Connector for
#22 to #12 AWG wire. Screws are
#6-32 x 5/16 in. for ring or spade
lugs, 5/16 in. wide maximum.
Mounts on standard 9080GH
track or 35 mm DIN 3 track.
1.20
.68
1 or 2 Conductors
Per Screw
#1222
Circuit Isolating Switchd
with self-lifting pressure
connectors
for #18 to #10 AWG wire.
Mounts on standard 9080GH
track or 35 mm DIN 3 track.
8.10
1.00
1
1
1
1–4
1–4
#10
#12
#14
#16
#18
Slip-on Connectors for #22 to
#12 AWG wire. Tabs accept
0.250 x 0.032 in. slip-on connectors
Mounts on standard 9080GH
track or 35 mm DIN 3 track.
1.70
1.00
1–2
1–2
1–2
1–2
1–2
1–2
#12
#14
#16
#18
#20
#22
Transient Voltage Suppressors f
with box lug connectors
for #18 to #10 AWG wire.
Mounts on standard 9080GH
track or 35 mm DIN 3 track.
13.80
1.10
1
1
1
1–2
1–4
#10
#12
#14
#16
#18
Fuse Block for 13/32 in. Dia. x 1-1/2 in. ferrule fuse with self-lifting
pressure connectors. Fuse
puller is included as standard.
Fuses are not included.
Mounts on standard 9080GH
track or 35 mm DIN 3 track.
7.80
1.00
1
1
1
1–4
1–4
#10
#12
#14
#16
#18
Blown Fuse Indicator/
Pullers are neon pilot
lights which plug on to the
fuse in a standard Type
GF6 fuse block.
120–240 V
7.90
277–600 V
7.90
a
Orders must specify the standard package quantity or multiples of that quantity.
b
These maximum current values assume the use of insulated copper conductors with 75oC temperature rating, and are calculated based on NEC Article 310, Table 310-16. In most cases this value is the maximum ampacity of that wire or combination of wires (as listed in the above table) which has the greatest current carrying capacity. The actual allowable current for a particular application depends on the number, size, insulation class, and other characteristics of the wires used. The lower of the UL and CSA ratings are shown below.
c
One end-barrier is required for each assembly of like sections.
d
Not intended to make or break a live circuit. Power must be disconnected from the circuit before operation of the switch.
e
Fuse puller is supplied as standard with Class 9080 Type GF6 fuse block. The 9080GH63 is a replacement fuse puller.
f
Modules have RC circuitry for suppressing transient voltage, generated when opening a coil circuit, to approximately 200% of the peak line voltage, when used with 120 V coils. Type GT6 is suitable for use with Square D Class 8501 Type X, K, R and C relays or Square D Type S starters and contactors, Sizes 00-2.
File
CCN
E60616
XCFR2
File
Class
LR62144
6228 01
File
CCN
E63698
ZTFR
File
Class
LR25490
184-N-90