Digest 174 Quick Page Locator Enter a page number from our paper catalog to go directly to that page in our online catalog. Example: 5 - 3
Pressure Switches Type FHG—PumptrolTM Compressor Pressure Switch Class 9013 / Refer to Catalog 9013CT9701 ● Class 9013 Type FHG pressure switches are designed for the control of small electrically driven air compressors. ● Contacts open on pressure rise. ● Diaphragm actuated. ● See page 22-15 for the following:Electrical RatingsApplication Data ● See page 22-21 for repair parts kits. Table 22.11: Selection Tables Description NEMA 1 Enclosure Adjustable Cut-out Range IncreasingPressure (psig) ApproximateDifferentialNon-adjustable (psig) Poles PressureConnection Lower hp Higher hp Type $ Price Type $ Price 40-100 20 2 1/4" NPSF (Internal) FHG2 18.20 FHG22 26.60 3/8" NPSF (Internal) FHG3 18.20 — — 1/4" Four Way FHG4 23.40 FHG24 31.70 1/4" NPT (External) FHG9 18.20 FHG29 26.60 70-150 30 2 1/4" NPSF (Internal) FHG12 18.20 FHG32 26.60 3/8" NPSF (Internal) FHG13 18.20 FHG33 26.60 1/4" Four Way FHG14 23.40 FHG34 31.70 1/4" NPT (External) FHG19 18.20 FHG39 26.60 100-200 40 2 1/4" NPSF (Internal) FHG42 18.20 FHG52 26.60 1/4" Four Way FHG44 23.40 FHG54 31.70 1/4" NPT (External) FHG49 18.20 FHG59 26.60 Table 22.12: Special Features and Modifications for Type FHG Description Form $ Price Addition Standard Pack of 20 Switches C2O — Addition of a Second Ground Screw G4a 0.32 Maintained Manual Cut-out Lever (AUTO-OFF) M1 3.40 Pulsation Plug—Factory order only, available only on 1/4-inch fittings, not to include 4-way P 0.49 Salt Water Flange (1/4 NPSF Internal Only) Qa 16.60 1/2" Conduit Bushing—1/2" Long Thread—on Left T 2.70 1/2" Conduit Bushing—1/2" Long Thread—on Right T1 2.70 Slip-On Connectors (Load Side Terminals Only) U 0.32 Slip-On Connectors (Line and Load Terminals) U2 0.64 Factory Sealed Range Stud W 0.32 Two-Way Pressure Release Valve X 6.90 Quick Connect Two-Way Pressure Release Valve (for use with Polyflow® Tubing) X1 11.80 Black Cover Z22 — a Can be field installed. Nameplate should then be marked with the FORM letter and maintenance and ordering records corrected. Table 22.13: Type F—Net Weight, 1-1/8 lb Switch Type A in. mm FSG1, FYG1 1-1/32 26 FHG2, 12, 22, 32, 42, 52FRG2, FSG2, FYG2 2-29/32 23 FHG3, 13, 33FRG3, FSG3, FYG3 1-9/32 33 FHG9, 19, 29, 39, 49, 59FSG9, FYG9 1-3/32 28 Table 22.14: Pressure Code (fixed differential)b Settings Code Off at 100 psi J27 Off at 110 psi J37 Off at 115 psi J38 Off at 120 psi J69 Off at 125 psi J52 Off at 135 psi J39 Off at 140 psi J68 Off at 155 psi J40 Off at 150 psi J55 Off at 175 psi J59 Specify other pressure J99 b The existence of a code does not imply that the code is available for any or all devices. Ordering Information 1. Specify Class 9013 Type FHG. 2. Select pressure code from Pressure Code Table at left and add code designation to end of typenumber. Be sure that the pressure code falls within the limits of the device as shown in thedevice listings. 3. If special features are desired, add the appropriate Form letter to the Class and Type. Arrange Form letters in alphabetical order when ordering more than one special feature. 4. Place packaging code in alphabetical order with other forms when ordering.For standard pack of 20 devices per box: C20 (refer to discount schedule CP7)For individually packaged devices: leave blank (refer to discount schedule CP7I) If no packaging code is indicated, devices will be shipped individually packaged. File E12158 CCN NKPZ File LR25490 UL Listed control equipment. However, Type 4 must have Form T or T1; otherwise these Types are component recognized.If conduit or pressure line is rigid, UL; if both are flexible, UR. CP7 CP7I Discount Schedule Modified1/17/08
Release Date: 03/31/2007Modification Date: 1/17/2008