Page 21-29
click here to download PDF version
Download PDF
Square D > On-line Catalog > Products > Limit Switches > Limit Switches: XCKML—General Specifications and Complete Devices

navigation start Table of Contents Previous Next Index end navigtion


Telemecanique

Digest 174 Quick Page Locator
Enter a page number from our paper catalog to go directly to that page in our online catalog.
Example: 5 - 3

Section - Page
-

Limit Switches

XCKML—General Specifications and Complete Devices

Refer to Catalog 9006CT0101

XCKML is a general duty limit switch, larger than the XCKL, for applications such as machine tools, material handling, and other applications where electrical redundancy and contact state signaling are required.
Key features include:
Feature Fingersafe® contact block
Lever operated—positive lever to shaft positioning to ensure the direct opening feature.
Direct opening contacts meet IEC 947-5-1 requirements for positive opening contacts.
Table 21.81:
By 30o cam
~ AC-15; A300 or Ue = 240 V, le = 3 A (for make and break ratings see XCKL page 21-27)
DC-13; Q300 or Ue—250 V, le = 0.27 A conforming to IEC 947-5-1 Appendix A, EN 60 947-5-1
Screw and captive cable clamp terminals.
Clamp capacity: minimum 1 x 0.34 mm2, maximum: 2 x 1.5 mm2 or 1 x 2.5 mm2 depending on contact.
Tightening torque: minimum 0.8 N•m, maximum 1.2 N•m
Table 21.82:
Thermoplastic roller
lever plunger. Horizontal
actuation in 1 direction
Thermoplastic
roller lever a
Two contact blocks,
2-pole 1 N.C. + 1 N.O.
snap action
Two contact blocks,
2-pole 1 N.C. + 1 N.O.
break before make,
slow break
a
Adjustable throughout 360o in 5o steps, or in 90o steps by reversing the notched washer.
Discount Schedule

navigation start Table of Contents Previous Next Index end navigtion


Release Date: 03/31/2007
Modification Date: 1/17/2008