Page 21-10
click here to download PDF version
Download PDF
Square D > On-line Catalog > Products > Limit Switches > Factory Modifications (Forms): Type C

navigation start Table of Contents Previous Next Index end navigtion
Square D


Digest 174 Quick Page Locator
Enter a page number from our paper catalog to go directly to that page in our online catalog.
Example: 5 - 3

Section - Page
-

Factory Modifications (Forms)

Type C

Class 9007 / Refer to Catalog 9006CT0101

Table 21.12:
Special Features (Do not apply to Types CF or CR unless noted)—Not Field Installable, Except Where Noted
$ Price
Addition
Receptacle is furnished with a wiring hole and a gasket on the base.
Available on standard and compact types. Replaces existing Type B installations if new hole is
drilled to match knockout. Supersedes Type C with Form Y2051.
Special Chemical Resistant Coating (Includes fluorocarbon [VITON] seals—Y140, and stainless steel head and body screws)
L3   
Low TemperatureLever Types Only: Limit (Position) switch will operate in an ambient temperature range of -40o F to 185o F (standard limit switch ambient temperature
range is -20o F to 185o F). Minimum temperature is based on the absence of freezing moisture or water. 
Y128  
Substitution of fluorocarbon (VITON) gaskets and seals on:
 Lever arm type, standard box (shaft seals on lever arm types are fluorocarbon (VITON) as standard)
 Lever arm type, compact box (shaft seals on lever arm types are fluorocarbon (VITON) as standard)
 Plunger type, standard box 
 Plunger type, compact box 
 Substitution of fluorocarbon (VITON) boot only on plunger type switches
   9.50
One pole, normally closed, slow make-slow break, direct acting contact mechanism substituted for standard snap switch on Types C52, C54, CF53 and CR53 devices.
This mechanism was designed for use in emergency overtravel applications. The movable contact of this basic switch unit is acted upon directly by the actuating
mechanism of the limit switch and is not dependent upon the force exerted by a snap switch blade or spring to open the circuit. Because these contacts are slow make-
slow break, they are best suited for applications where they are not actuated during normal operation, but only if abnormal overtravel is encountered.
AC—NEMA A600
Max. Current—35% Power Factor
Continuous
Carrying A
Continuous
Carrying A
6  
3  
60  
a
Type C52 compact unit ratings at 125 Vdc—same ratings as C54, CF53 and CR53 at other voltages.
Table 21.14:
Adapters—Field Installable
Switch with adapter plate permitting substitution of any
Type C switch with standard box for any Type T switch with
Style B baseplate
Adapter plate to allow direct substitution of Type C plunger
switches for Type B plug-in plunger switches—use only if
there is a problem in lining up cam tracks
  Standard Box
  Compact Box
12.60
12.60
Adapter Plate Kit permitting direct substitution of any
Type C lever arm switch with standard box for ANY
Type AW lever arm switch
Conduit connection adapter—male 1/2" NPT on one end,
female 20 mm on other end
Table 21.15:
Mushroom Button For Palm Operated Turret Head
Also see Type C Palm Operated Switches
Discount Schedule