Digest 174 Quick Page Locator Enter a page number from our paper catalog to go directly to that page in our online catalog. Example: 5 - 3
Control Stations and Enclosures Type KY 30 mm Control Stations Class 9001 / Refer to Catalog 9001CT0001 Control Stations Enclosures have sufficient depth to accommodate two contact blocks in tandem (total of four blocks) on non-illuminated operators and two contact blocks side-by-side on illuminated operators. Table 19.308: Assembled Control Stations—UL Types 1, 3, 4 and 13/NEMA 1, 3, 4 and 13 a Die Cast Zinc Enclosures No of Units Legend Plate Marking And Features Type $ Price Consists of Enclosure Operators Contact Blocks Legend Plates 1 Hand-Off-Auto (Selector Switch) Hand-Off-Auto (Sel. Switch) (With Sealed Contacts) Jog-Run (Selector Switch) Off-On (Selector Switch) Off-On (Selector Switch) (With Sealed Contacts) KYK111 KYK121 b KYK18 KYK110 KYK122 b 162.00 228.00 162.00 162.00 228.00 KY1 KY1 KY1 KY1 KY1 KS43B KS43B KS11B KS11B KS11B KA1 KA51 KA1 KA1 KA51 KN260 KN260 KN242 KN244 KN244 Red 120 Vac Pilot Light Start Start (With Sealed Contacts) Start (Mushroom Button) Stop Stop (Mushroom Button) KYK120 b KYK11 KYK125 b KYK12 KYK13 KYK14 180.00 152.00 219.00 180.00 152.00 180.00 KY1 KY1 KY1 KY1 KY1 KY1 KP1R31 KR1B KR1B KR4B KR1R KR4R — KA1 KA51 KA1 KA1 KA1 — KN201 KN201 KN201 KN202 KN202 Stop (With Lockout) Stop (With Sealed Contacts and Lockout) Stop Mushroom (With Sealed Contacts and Lockout) To Stop—Break Glass To Stop—Break Glass (Red Enclosure) KYK15 KYK124 b KYK123 b KYK116 KYK117 180.00 248.00 276.00 219.00 219.00 KY1 KY1 KY1 KY1 KY1S1 KR3R,K4 KR3R,K4 KR4R,K4 K15 K15 KA1 KA51 KA51 KA1 KA1 KN202 KN202 KN202 KN799RP KN799RP 2 Forward-Reverse Jog-Stop (Lockout on Stop) On-Off On-Off (With Sealed Contacts) On-Off (Maintained Contact) Open-Close KYK24 KYK224 KYK218 KYK222 b KYK221 KYK26 219.00 248.00 219.00 351.00 219.00 219.00 KY2 KY2 KY2 KY2 KY2 KY2 KR1B,KR1B KR1B,KR3R,K4 KR1B,KR3R KR1B,KR3R KR11GR KR1B,KR1B KA1,KA1 KA1,KA1 KA1,KA1 KA51,KA51 KA1 KA1,KA1 KN206,KN207 KN218,KN202 KN203,KN204 KN203,KN204 KN203,KN204 KN209,KN208 Start-Stop Start-Stop (With Sealed Contacts) Start-Stop (Lockout on Stop) Start-Stop (Maintained Contact) Start-Stop (With Maintained Sealed Contacts) Start-Stop (Mushroom on Stop) Up-Down KYK21 KYK223 b KYK23 KYK27 KYK220 b KYK22 KYK25 219.00 351.00 248.00 219.00 285.00 248.00 219.00 KY2 KY2 KY2 KY2 KY2 KY2 KY2 KR1B,KR3R KR1B,KR3R KR1B,KR3R,K4 KR11GR KR11GR KR1B,KR4R KR1B,KR1B KA1,KA1 KA51,KA51 KA1,KA1 KA1 KA51 KA1,KA1 KA1,KA1 KN201,KN202 KN201,KN202 KN201,KN202 KN201,KN202 KN201,KN202 KN201,KN202 KN211,KN210 3 Forward-Reverse-Start-Stop Forward-Reverse-Stop Forward-Reverse-Stop (Lockout on Stop) Forward-Reverse-Stop (With Sealed Contacts and Lockout on Stop) High-Low-Stop KYK35 KYK31 KYK326 KYK322 b KYK34 305.00 294.00 323.00 522.00 294.00 KY3 KY3 KY3 KY3 KY3 KS11B,KR1B,KR3R KR1B,KR1B,KR3R KR1B,KR1B,KR3R,K4 KR1B,KR1B,KR3R,K4 KR1B,KR1B,KR3R KA1,KA1,KA1 KA1,KA1,KA1 KA1,KA1,KA1 KA51,KA51,KA51 KA1,KA1,KA1 KN239,KN201,KN202 KN206,KN207,KN202 KN206,KN207,KN202 KN206,KN207,KN202 KN214,KN215,KN202 Jog/Run-Start-Stop Open-Close-Stop Open-Close-Stop (Lockout on Stop) Open-Close-Stop (With Seated Contacts and Lockout on Stop) Red 120 Vac Pilot Light-Start-Stop KYK36 KYK33 KYK327 KYK323 b KYK317 305.00 294.00 323.00 522.00 314.00 KY3 KY3 KY3 KY3 KY3 KS11B,KR1B,KR3R KR1B,KR1B,KR3R KR1B,KR1B,KR3R,K4 KR1B,KR1B,KR3R,K4 KP1R31,KR1B,KR3R KA1,KA1,KA1 KA1,KA1,KA1 KA1,KA1,KA1 KA51,KA51,KA51 KA2,KA3 KN242,KN201,KN202 KN209,KN208,KN202 KN209,KN208,KN202 KN209,KN208,KN202 KN200,KN201,KN202 Red 120 Vac Pilot Light-Start-Stop (With Sealed Contacts) Red 120 Vac/dc Pilot Light-Start-Stop Up-Down-Stop Up-Down-Stop (Lockout on Stop) Up-Down-Stop (With Sealed Contacts and Lockout on Stop) KYK321 b KYK324 KYK32 KYK325 KYK328 b 456.00 323.00 294.00 323.00 522.00 KY3 KY3 KY3 KY3 KY3 KP1R31,KR1B,KR3R KP38R31,KR1B,KR3R KR1B,KR1B,KR3R KR1B,KR1B,KR3R,K4 KR1B,KR1B,KR3R,K4 KA51,KA51 KA1,KA1 KA1,KA1,KA1 KA1,KA1,KA1 KA51,KA51,KA51 KN200,KN201,KN202 KN200,KN201,KN202 KN211,KN210,KN202 KN211,KN210,KN202 KN211,KN210,KN202 a Control stations are UL Listed for use in areas classified as Class II Division 2 Group G and Class III. b Control station consists of components that are UL Listed for use in Class I, Division 2, Groups A, B, C or D. Dimensions see catalog 9001CT0001 When ordering, please specify: ▪ Quantity ▪ Class Number ▪ Type or Catalog Number CP1 Discount Schedule Related Topics Type KYSS300 and SKY201 page 19-104 Standard Assembled Control Stations page 19-103 to 19-104 Custom Assembled Control Stations page 19-102
Release Date: 03/31/2007Modification Date: 1/17/2008