Starters Accessories TeSys™ GV2 and GV3 Manual Starters and Protectors Refer to Catalog 2502CT0001 Table 18.125: Voltage Trips Only one trip or fault signaling contact can be installed per GV2/GV3 device. Description Characteristics Voltage Frequency Catalog Numbera $ Price Voltage trips GV2 & GV3 Undervoltage orShunt trip(external mount,1 block right side only) 24 V 50 Hz GVA•025 54.00 60 Hz GVA•026 48 V 50 Hz GVA•055 60 Hz GVA•056 100–110 V 50/60 Hz GVA•107 110–115 V 50 Hz GVA•115 60 Hz GVA•116 120–127 V 50 Hz GVA•125 127 V 60 Hz GVA•115 200 V 50 Hz GVA•207 200–220 V 60 Hz GVA•207 220–240 V 50 Hz GVA•225 60 Hz GVA•226 380–400 V 50 Hz GVA•385 60 Hz GVA•386 415–440 V 50 Hz GVA•415 415 V 60 Hz GVA•416 440 V 60 Hz GVA•385 480 V 60 Hz GVA•415 500 V 50 Hz GVA•505 600 V 60 Hz a To order an under voltage trip: replace the bullet ( •) with a U, example: GVAU025. To order a shunt trip: replace the bullet ( •) with an S, example: GVAS025. Table 18.126: Auxiliary Contact Blocks Description MountingLocation Max. No. of Blocks Contact Type Sold in lots of Catalog Number $ Price Instantaneous auxiliary contacts GV2 + GV3 Frontbg 1 N.O. or N.C.c 1 GVAE1 14.50 N.O. + N.C. 10 GVAE11e 23.80 N.O. + N.O. 1 GVAE20e 23.80 Left Hand Side 2 N.O. + N.C. 1 GVAN11e 23.80 N.O. + N.O. 1 GVAN20e 23.80 Fault signaling contact + instantaneous auxiliary contact GV2 + GV3 Left Hand Sided 1 N.O. (fault) + N.O. 1 GVAD1010 36.20 N.O. (fault) + N.C. 1 GVAD1001 36.20 N.C. (fault) + N.O. 1 GVAD0110 36.20 N.C. (fault) + N.C. 1 GVAD0101 36.20 Short circuit signaling contact GV2 + GV3 Left Hand Side 1 SPDT 1 GVAM11 23.80 b Mounting of a GVAE contact block or a GV2AK00 visible isolation block on GV2P. c Choice of N.C. or N.O. contact operation, depending on which way the reversible block is mounted. d The GVAD is always mounted next to the starter. e For spring terminals add 3 to the catalog number. Example: GVAE113 f One trip or one fault signaling can be fitted per GV3. g Cannot be used with GV2GH7 insulator. Table 18.127: Voltage Trips–Technical Data (GV2AU, GV2AS) Rated Voltage–660 Vac Model Inrush Sealed Pick-Up Voltage Drop-Out Voltage Operating Timeh GVAU 12 VA / 8 W 3.5 VA / 1.1 W 0.8 to 1.1 0.35 to 0.7 10 to 15 ms GVAS 14 VA / 10.5 W 5 VA / 1.6 W 0.7 to 1.1 0.2 to 0.75 10 to 15 ms h From the loss of voltage at the trip terminals to the opening of the starter contacts. Table 18.128: GV3P Accessories Description For GV3P Catalog Number $ Price Set of 3-pole 115 A busbars (tap-offs: 3, pitch: 64 mm) GV3P•• GV3G364 30.00 Cover “Larger Spacing” UL 508 type E (Only one cover required on supply side) GV3P•• GV3G66 12.00 IP 20 cover(Two covers required per starter) GV3P•• LAD96570 8.00 Padlocking deviceFor use with up to 4 padlocks (not supplied)Ø 6 mm shank maximum GV3P•• GV3P••• GV2V03 130.00 CP10 I11 Discount Schedule Modified 1/17/08
Release Date: 03/31/2007Modification Date: 1/17/2008