Digest 174 Quick Page Locator Enter a page number from our paper catalog to go directly to that page in our online catalog. Example: 5 - 3
Contactors and Accessories TeSys™ K-Line Contactors and Accessories Refer to Catalog 8502CT9901 Table 18.100: Instantaneous auxiliary contact blocks Clip-on front mounting, 1 block per contactor and 2 blocks per pair of mechanically interlocked contactors. Type of connection Auxiliary Contacts CatalogNumber $ Price N.O. N.C. Screw clamp 2 — LA1KN20 14.20 — 2 LA1KN02 14.20 1 1 LA1KN11 14.20 4 — LA1KN40 a 27.30 3 1 LA1KN31 a 27.30 2 2 LA1KN22 a 27.30 1 3 LA1KN13 a 27.30 — 4 LA1KN04 a 27.30 Slip-on 1 x .250" or 2 x .110" 2 — LA1KN207 14.20 — 2 LA1KN027 14.20 1 1 LA1KN117 14.20 4 — LA1KN407 a 27.30 3 1 LA1KN317 a 27.30 2 2 LA1KN227 a 27.30 1 3 LA1KN137a 27.30 — 4 LA1KN047 a 27.30 a Block of 4 contacts cannot be used with LP4K or LP5K contactors. Table 18.101: Electronic time delay auxiliary contact blocks Clip-on front mounting, 1 block per contactor and 2 blocks per pair of mechanically interlocked contactors. 24 to 48 Vac or Vdc On-delay 1 to 30 SPDT LA2KT2E 32.80 110 to 240 Vac On-delay 1 to 30 SPDT LA2KT2U 32.80 Relay outputs, with single pole double throw, 240 Vac/dc, 2 A max. Control voltage, from 0.85 to 1.1 Uc. Maximum switching capacity 250 VA / 150 W Operating temperature: -10 to + 60¡C (14 to 140¡F) Reset time: 1.5 s during time delay, 0.5 after time delay Table 18.102: Suppressor Module with incorporated LED indicator Clip-on front mounting 12 to 24 Vac and dc Varistor 5 LA4KE1B b 9.80 32 to 48 Vac and dc Varistor 5 LA4KE1E b 9.80 50 to 129 Vac and dc Varistor 5 LA4KE1FC b 9.80 130 to 250 Vac and dc Varistor 5 LA4KE1UG b 9.80 12 to 24 Vdc Diode + Zener 5 LA4KC1B c 9.80 32 to 48 Vdc Diode + Zener 5 LA4KC1E c 9.80 220 to 250 Vac RC 5 LA4KA1U d 9.80 b Protection by limitation of the transient voltage to 2 Uc maximum. Maximum reduction of the transient voltage peaks. Slight time delay on drop-out (1.1 to 1.5 times normal). c No overvoltage or oscillation frequency. Polarized component. Slight time delay on drop-out (1.1 to 1.5 times normal). d Protection by limitation of the transient voltage to 3 Uc maximum and limitation of the oscillation frequency. Slight time delay on drop-out (1.2 times normal). Table 18.103: Paralleling Links Description Sold inlots of CatalogNumber $ Priceeach For 2 poles with screw-clamp terminals 4 LA9E01 2.20 For 4 poles with screw-clamp terminals 2 LA9E02 3.50 Table 18.104: Power Connectors Description Sold inlots of CatalogNumber $ Priceeach Set of 6 power connections for reversing contactors with screw-clamp terminals 100 LA9K0969 0.06 Set of 4 power connections for changeover contactors with screw-clamp terminals 100 LA9K0970 6.20 Table 18.105: Marking strips Description Sold inlots of CatalogNumber $ Priceeach Clips onto front of the contactor 100 LA9D90 .06 Table 18.106: Accessories for overload relays Description Type of Connection Catalog Number $ Price Terminal block for separate clip-on mounting of the overload relay onto 35 mmomega rail (AM1DP200) Screw-clamp LA7K0064 11.90 I11 Discount Schedule Modified 1/17/08
Release Date: 03/31/2007Modification Date: 1/17/2008