Contactor Accessories TeSys™ D-Line & F-Line Auxiliary Contacts, Time Delay, Mechanical Latch Refer to Catalog 8502CT9901 Table 18.15: Standard, instantaneous auxiliary contact blocks Snap-On Mounting Number of Contacts Composition Catalog Number a $ Price N.O. N.C. To front of LP●D40–D80, LC● DT20–DT40 (4P), LC●D09–D150a or To right side of LC ● F 4 a 2 2 LADN22 b 41.50 1 3 LADN13 b 41.50 4 0 LADN40 b 41.50 0 4 LADN04 b 41.50 3 1 LADN31 b 41.50 2 c 2 c LADC22 bc 41.50 2 1 1 LADN11 b 20.70 2 0 LADN20 b 20.70 0 2 LADN02b 20.70 To front of LP●D40–D80, LC ●DT20–DT40 (4P), LC● D25 to D150 or To left side of LC●F 1 1 0 LADN10 d 13.10 0 1 LADN01 d 13.10 To side of LC●D09 to D150 only (not for use on F-LIne) 2 1 1 LAD8N11 e 20.70 2 0 LAD8N20 e 20.70 a For low consumption coils, only one front-mounted two-contact block allowed. No side-mounted contact blocks allowed. b For spring terminal versions of these blocks, add a “3” to the end of the catalog number. For example, LADN223. c Including 1 N.O. + 1 N.C. make before break overlapping contacts. d This block cannot be added to the LC1D 09 to D32 contactors; a maximum of 2 blocks can be mounted on the LC1/LP1 D40 to D80 contactors only. e 1 block may be added to the left side of the LC1D 09 to D32, AC coils only; 1 block may be added to each side of the LC1D 40 to D80 contactors, AC coils only. Cannot be installed on D-Line contactors with DC coils. Table 18.16: Instantaneous blocks with dust-tight auxiliary contacts (IP54) NEMA 12 Snap-On Mounting Standard Contacts Dusttight Contacts Catalog Number $ Price N.O. N.C. N.O. N.C. To front of LP● D40–D80, LC ● DT20–DT40 (4P), LC ● D09 to D80 or To right side of LC ●F — — 2 — LA1DX20 65.00 2 — 2 — LA1DZ40 82.00 1 1 2 — LA1DZ31 82.00 — — 2 — LA1DY20f 77.00 f Device supplied with 4 ground terminal points. Table 18.17: Pneumatic time delay contact blocks Snap-On Mounting Time Delay Contacts Type Range of Time Delay Catalog Number h $ Price N.O. N.C. To front ofLP● D40–D80, LC● DT20–DT40 (4P), LC ● D09 to D150 or To right side ofLC● F 1 1 On energization(on delay) 0.1 to 3 sg LADT0 131.00 0.1 to 30 s LADT2 131.00 10 to 180 s LADT4 131.00 1 to 30 si LADS2 131.00 1 1 On de-energization(off-delay) 0.1 to 3 sg LADR0 131.00 0.1 to 30 s LADR2 131.00 10 to 180 s LADR4 131.00 g Scale range is expanded between 0.1 and 0.6 seconds on the dial for more accurate settings at the lower end of the range. h For spring terminal versions of these blocks, add a “3” to the end of the catalog number. For example, LADT023. i With switching time of 40 ms ± 15 ms between the opening of the N.C. contact to the closing of the N.O. contact. Table 18.18: Mechanical latch blocks with manual or electrical unlatch (D-Line only) Front snap-on mounting onto Application Catalog number to be completed by the code corresponding to the coil voltage $ Price LC●/LP ●D09 to D65 For silent operation and energy conservation LA6DK10jk 77.00 LC1 D80 to D150 LP1 D80 For silent operation and energyconservation LA6DK20jk 77.00 j Does not include internal coil clearing contact. k Complete catalog number by adding coil voltage code. For example: LA6DK10F. Table 18.19: Coil Voltage Codes for LA6DK mechanical latch blocks Volts 12 24 32/36 42/48 60/72 100 110/127 200/208 220/240 380/415 440/480 500/600 AC or DC J B