Square D > On-line Catalog >
Products
>
NEMA Contactors and Starters > Thermal Overload Relays—NEMA Rated: Solid State Overload Relay, Motor Logic and Motor Logic Plus |
|
|
|
Section - Page
|
Thermal Overload Relays—NEMA Rated
Solid State Overload Relay, Motor Logic® and Motor Logic Plus
Class 9065 / Refer to Catalog 9065CT9701
Motor Logic
Base Unit relays feature: 3 to 1 adjustment for trip current; phase loss and unbalance protection; direct replacement for Type S melting alloy; and LED power indication. They are ambient insensitive and self–powered. Electrical remote reset is also available.
![]()
Motor Logic SSOLR are designed to protect 50/60 hertz three-phase AC motors from overload, phase unbalance and phase loss conditions. Open Delta systems or grounded B-phase systems are difficult to balance and could cause the Motor Logic SSOLR to trip. For applications of this nature, it is recommended that bi-metallic overload relays (Form B12) be used.
Table 16.285:
a Size 00c, 0, and 1 are supplied without lugs. Lower amperage loads can be protected by looping of power wires. Lugs are available, see page 16-124.
Table 16.286: Base Unit: Replacement SSOLR for Retrofit of Square D Type S Starter
Solid State Overload Relay
600 Vac Maximum Locate 8536 Starter in this column Full Load Current Range (Amperes) 0b1b3e4e5d
b Lug - Bar Kits are available for Size 00c, 0 and 1. Lower amperage loads can be protected by looping of power wires. See page 16-124.
c Size 5 Replacement Overload is only for existing NEMA S starters with MOTOR LOGIC overload relay. External CTs and additional components are not included.
d Size 5 is a complete drop-in replacement for Square D NEMA S melting alloy, bimetallic, and Y500 overload relays only.Feature Unit relays include all of the features found on the Base Unit relays plus: switch selectable trip class; Class II ground fault detection; and direct replacement for Type S melting alloy. Electrical remote reset is also available.
Table 16.287: Feature Unit: For Separate Mounting Solid State Overload Relay
600 Vac Maximum 1.5–4.5f
f
g NEMA Size 00B and 00C are not actual NEMA sizes. These designations are used to differentiate the lower FLA of these devices from the NEMA Size 00 Motor Logic Solid State Overload Relay.
Table 16.288: Feature Unit: Replacement SSOLR for Retrofit of Square D Type S Starter
Solid State Overload Relay
600 Vac Maximum Order Class 9065 Overload Relay from this column Full Load Current Range (Amperes) 5i5j6i7i 1.5–4.53–915–4530–90180–540270–810
h Size 00B, 00C, 0, and 1 are supplied without lugs. Lower amperage loads can be protected by looping of power wires.
i Size 5, 6 and 7 Replacement Overloads are only for existing NEMA S starters with MOTOR LOGIC overload relay. External CTs and additional components are not included.
j Size 5 is a complete drop-in replacement for Square D NEMA S melting alloy, bimetallic, and Y500 overload relays only.
k NEMA Size 00B and 00C are not actual NEMA sizes. These designations are used to differentiate the lower FLA of these devices from the NEMA Size 00 Motor Logic Solid State Overload Relay.Motor Logic Plus
Motor Logic Plus solid state overload relay is separately powered and fully programmable. It is designed to protect 200–480 Vac or 600 Vac, 3-phase AC motor applications. The SSOLR has one Form C relay output rated for 300 Vac maximum.
Class 9065 SP Solid State
Overload Relay Product
Description Current Range 0.5–2.3 A2.0–9.0 A6.0–27.0 A10.0–45.0 A20.0–90.0 A60.0–135.0 A120.0–270.0 A240.0–540.0 A
Table 16.290: Forms for factory addition to 8536 Open Style only 0.5–2.3 A2.0–9.0 A6.0–27.0 A10.0–45.0 A20.0–90.0 A60.0–135.0 A120.0–270.0 A240.0–540.0 A No Modification for 200–480 VExample
Motor Logic Plus overload relay with a current range of 6–27 A and modifications to add communication module for an open style starter package.
|
|
Release Date: 03/31/2007 |