Full Voltage ContactorsNEMA Rated

 

Class 8536 / Refer to Catalog 8502CT9701

General Information

Type S magnetic starters are used for full-voltage starting and stopping of AC squirrel cage motors. Motor overload protection is provided via melting alloy type thermal overload relays. Type S starters are available in NEMA Sizes 00 through 7, and are designed for operation at 600 Vac, 50 to 60 Hz.

Solid State Overload Relay Protection (MOTOR LOGIC®)

These ambient insensitive overload relays are available on Sizes 00 through 6 and standard on size 7. They provide phase loss, phase unbalance protection and a power LED indication. To order, add Form H10 (for Class 10), H20 (for Class 20), or H30 (for selectable trip class protection). For more information about MOTOR LOGIC, see pages16-98, 16-112 and 16-113.

3-Pole Polyphase—600 Vac Maximum—50–60 Hz

Note that prices shown do not include thermal units. Devices require 3 thermal units (Sizes 00–6). Standard trip thermal units are $14.30 each. See page 16-129 for selection information.
Table 16.38:
NEMA
Size
Continuous
Current
Ratings
Motor
Voltage
NEMA 1
General Purpose
Enclosure
NEMA 4 & 4X
Watertight, Dusttight
Brushed Stainless Steel
Enclosure (Size 0-5)a
NEMA 4X
Watertight, Dusttight,
Corrosion-Resistant
Glass-Polyester Enclosure
  9
   1-1/2
   1-1/2
 18
200
230
460
575
 27
200
230
460
575
    7-1/2
    7-1/2
 10
 10
 45
200
230
460
575
 10
 15
 25
 25
 90
200
230
460
575
 25
 30
 50
 50
200
230
460
575
200
230
460
575
200
230
460
575
230
460
575
Table 16.39:
24c
120 d
208
240
277
480
600
Specify

110

220

440
550
Specify
V01
V02
V08
V03
V04
V06
V07
V99
No Charge
No Charge
No Charge
No Charge
No Charge
No Charge
No Charge
c
24 V coils are not available on Sizes 4–7. On Sizes 00-3, where 24 V coils are available, Form S (separate control) must be specified
(i.e., order as 8536SBO2V01S).
d
120 Volt Polyphase contactors are wired for separate control. Form S (separate control) must be specified (i.e., order as 8536SCO2V02S).
*
For voltage codes used with control transformers, see page 16-111.
Form S (separate control) is used when a separate source of power is available for the control (coil) voltage.