Medical Products

Accessories

Class 4800 / Refer to Catalog 4800CT0301 or Pricing Document 4800PL0301

Accessories Panel

The Accessories Panel accommodates options typically found in the operating room environment, including receptacles, clock/timers, and music centers. Other options include relays for controlling “IN USE” lights for laser and X-ray.
5–20R (duplex red)
5–20R (single red)
6–20R
L6–20R
6–30R
L6–30R
1–8
Instructions: Combine the unit part numbers to build the desired panel. The catalog number must begin with “AP” and corresponding number to follow. For example, APCTCRMARMA4N4 will produce a panel containing a MCT12B clock/timer with a MCTCT remote control, a M5IAI remote alarm indicator, a AM/FM/CD multi-play music center, four HBL8310R receptacles, and four SLR3 ground jacks.
The purchase price includes the appropriate backbox. Some components may not be able to be installed with others, and may be considered as special items. Contact your nearest Schneider Electric sales office for all special item pricing.
X-ray Indicator/Receptacle Module
Supervisory Module for Controlled Panels
Receptacles quoted include a Hubbell 50/60 A, X-ray type 25000. For other receptacles, indicate the NEMA configuration after the Catalog Number. For example, XRIADINEMAL630R
Accessory –E booster power supply for three or more remote indicator alarms.
Digital Clock/Timers—UL® Listed
*
A complete clock/timer can be ordered using the catalog number MCT12BC. This includes the clock/timer, stainless steel trim and backbox. Remote control or battery pack must be ordered separately.
*
A complete surgical chronometer can be ordered using catalog number MCT14BC. This includes the chronometer, Remote control and both backboxes. All of these items are required for one complete unit.
Remote Alarm Indicators
The NEC® requires audible and visual alarm indication where isolation power is used (NEC 517-160).
Where Remote Alarm is
REQUIRED
Single gang remote with meter display
Included with all new panels
Panel- or wall-mounted; no face plate
Panel-mounted; includes face plate
Wall-mounted; includes face plate
Green, amber, and red indicating lights
and audible alarm mounted on front trim
Panel-mounted
in the room
Green, amber, and red indicating lights,
PUSH-TO-TEST button, audible alarm, and
milliammeter mounted on front trim a
Panel-mounted
in the room
Wall-mounted backbox not supplied.
Fits standard 2 gang box (3.5 in. deep)
Panel-mounted
outside the room
Wall-mounted 53008BB backbox required (backbox 4 in. H x 12 in. W x 4 in. D) a
Panel-mounted
outside the room
Wall mounted backbox not supplied.
Fits standard 4 gang box (3.5 in. deep) a
Panel-mounted
outside the room
*
PUSH-TO-TEST option for any of the above remotes—add PTT after the catalog number.
a
Includes meter for 5 mA LIM. For 2 mA LIM applications, change to
catalog number ORICAC. 2 mA analog meter available. Contact Schneider Electric.