Digest 174 Quick Page Locator Enter a page number from our paper catalog to go directly to that page in our online catalog. Example: 5 - 3
Medical Products Dual Output Voltage Panels Class 4800 / Refer to Catalog 4800CT0301 or Pricing Document 4800PL0301 The dual output voltage hospital isolation panel is a single ungrounded hospital isolation panel that can supply two different output voltages simultaneously. Similar to a standard distribution panel or load center, it can supply either 208/120 or 240/120 volts of ungrounded, isolated, single phase power using only one isolation transformer. Other hospital isolation panels can supply only one output voltage. The panel is ideally suited for renovation or surgical center projects. Interior Description (1) Primary voltage 2 = 208 V 3 = 240 V 4 = 277 V 5 = 480 V (2) Output voltage A = 120/208 V B = 120/240 V (3) Size rating of 120 V secondary winding (kVA)a 5 = 5.0 kVA 7 = 7.5 kVA 1 = 10.0 kVA (4) Number of 30 A green ground receptacles 0 = None 1 = One 2 = Two 3 = Three 4 = Four 5 = Five 6 = Six (5) Number of 120 V power receptacles 0 = None 1 = One 2 = Two 3 = Three 4 = Four 5 = Five 6 = Six (6) Type of 120 V power receptacles 0 = No 120 V receptacles R = 20 A, red hospital grade duplex I = 20 A, ivory hospital grade duplex B = 20 A, black hospital grade duplex T = 20 A, brown hospital grade duplex L = 20 A, black hospital-only locking type receptacle (Hubbell #23000HG or equivalent) (7) Configuration of 208 or 240 V receptacle #1b 0 = No 208 or 240 V receptacle X = Hubbell #IN16 494 (equivalent to Hubbell #25603) A = NEMA Type #6-15R B = NEMA Type #6-20R C = NEMA Type #6-30R D = NEMA Type #6-50R E = NEMA Type #L6-15R F = NEMA Type #L6-20R G = NEMA Type #L6-30R (8) Configuration of 208 or 240 V receptacle #2b 0 = No 208 or 240 V receptacle X = Hubbell #IN16494 (equivalent to Hubbell #25603) A = NEMA Type #6-15R B = NEMA Type #6-20R C = NEMA Type #6-30R D = NEMA Type #6-50R E = NEMA Type #L6-15R F = NEMA Type #L6-20R G = NEMA Type #L6-30R a 120 V section of panel interior will be factory loaded with 8-20/2 branch breakers. This panel section is field expandable to 16 branch breakers by ordering additional circuit breaker catalog numbers QO220. b 208 V or 240 V section of panel interior will be factory loaded with the correct circuit breaker to match the selected receptacle. If no receptacle is selected, this section of the panel interior is field expandable to 2 branch breakers by ordering catalog number QO220 through QO260. Total transformer kVA rating is the sum of the 120 V winding and the 208 V (or 240 V) winding. Catalog Numbering System Notes and Pricing Catalog # DVP (1)(2)(3)(4)(5)(6)(7)(8) Fill-in parenthesis from selections listed above. Interior Code Numbers (1) (2) (3) (4) (5) (6) (7) (8) Interior Catalog Number DVP 2 B 7 6 6 R X D 208/240 V receptacle #2 is NEMA Type 6-50R 208/240 V receptacle #1 is Hubbell IN16494 120 V power receptacles are red in color Six 120 V power receptacles