Dry Type 2.4, 5, and 15 kV

Three- and Single-Phase; 1201–15,000 Volts

Class 7432

1201–15,000 Volts Three-Phase Indoor Transformers

All transformers are built with 220oC insulation and 150oC temperature rise. For 115oC rise add 10% to price and F to catalog number. For 80oC rise add 20% to price and B to catalog number. Check with factory to verify dimensional changes and weights. For copper windings add 20%.
Standard high voltage taps: 4-2.5%, 2AN and 2BN. For
4-2.5% FCBN, add BN to catalog number.
Weight
(lbs)
112.5
150
225
300
112T( )H
150T( )H
225T( )H
00T( )H
 1400
 1600
 1900
 2100
Floor
Floor
Floor
Floor
28D
28D
29D
29D
500
750 b
1000 b
500T( )H
750T( )H
1000T( )H
124257.00
154230.00
 3200
 3900
 7400
Floor
Floor
Floor
31D
31D
33F
1500 b
2000 b
2500 b
1500T( )H
2000T( )H
2500T( )H
 9000
10900
12200
Floor
Floor
Floor
33F
34F
34F
112.5
150
225
300
500
112T( )H
150T( )H
225T( )H
300T( )H
500T( )H
2000
2200
2800
3300
5000
Floor
Floor
Floor
Floor
Floor
30D
30D
31D
31D
32F
750 b
1000 b
1500 b
750T( )H
1000T( )H
1500T( )H
6000
7400
9000
Floor
Floor
Floor
33F
33F
33F
2000 b
2500 b
3000 b
2000T( )H
2500T( )H
3000T( )H
10900
12200
15400
Floor
Floor
Floor
34F
34F
35F
a
Enclosures for indoor use only. Letters in parenthesis refer to enclosure styles on 14-8. Transformers suitable for outdoor use available on special order.
b
Dimensions and prices listed for 480 volt secondary only. For 240 V or 208 V, contact your local Schneider Electric sales office.
2.4
30 kV BIL
13
14
15
16
17
2400 Delta
2400 Delta
2400 Delta
2400 Delta
2400 Delta
208Y/120
480Y/277
240 Delta
480 Delta
600 Delta
5
30 kV BIL
18
19
20
21
22
23
25
26
27
28
29
30
31
4160 Delta
4160 Delta
4160 Delta
4160 Delta
4160 Delta
4160Y/2400
4160Y/2400
4160/2400
4800 Delta
4800 Delta
4800 Delta
4800 Delta
4800 Delta
208Y/120
480Y/277
240 Delta
480 Delta
600 Delta
240 Delta
480 Delta
600 Delta
208Y/120
480Y/277
240 Delta
480 Delta
600 Delta
15
60 kV BIL
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
7200 Delta
7200 Delta
7200 Delta
7200 Delta
7200 Delta
12000 Delta
12000 Delta
12000 Delta
12000 Delta
12000 Delta
12470 Delta
12470 Delta
12470 Delta
12470 Delta
12470 Delta
12470Y/7200
12470Y/7200
12470Y/7200
13200 Delta
13200 Delta
13200 Delta
13200 Delta
13200 Delta
13200Y/7620
13200Y/7620
13200Y/7620
13800 Delta
13800 Delta
13800 Delta
13800 Delta
13800 Delta
208Y/120
480Y/277
240 Delta
480 Delta
600 Delta
208Y/120
480Y/277
240 Delta
480 Delta
600 Delta
208Y/120
480Y/277
240 Delta
480 Delta
600 Delta
240 Delta
480 Delta
600 Delta
208Y/120
480Y/277
240 Delta
480 Delta
600 Delta
240 Delta
480 Delta
600 Delta
208Y/120
480Y/277
240 Delta
480 Delta
600 Delta

1201–15,000 Volts Single-Phase Indoor Transformers

All transformers are built with 220oC insulation and 150oC temp. rise. For 115oC rise add 10% to price and F to catalog number. For 80oC rise add 20% to price and B to catalog number, and check with factory for dimensional changes.
Standard high voltage taps: 4–2.5%, 2AN and 2BN. For 4–2.5% FCBN, add BN to catalog number.
Weight
(lbs)
167
250
333
167S( )H
250S( )H
333S( )H
45444.00
59253.00
72783.00
1500
2200
3000
Floor
Floor
Floor
28D
29D
29D
167
250
333
167S( )H
250S( )H
333S( )H
48777.00
63312.00
77478.00
1500
2200
3200
Floor
Floor
Floor
28D
29D
29D
167
250
333
167S( )H
250S( )H
333S( )H
56136.00
72705.00
86835.00
2400
3400
5000
Floor
Floor
Floor
31D
31D
31D
a
Enclosures for indoor use only. Letters in parenthesis refer to enclosure styles on 14-8. Transformers suitable for outdoor use available on special order.

Special Notes

1.
Distribution class lightning arresters are recommended as good practice, but are not included in the above prices. Arrester addition may affect dimensions. Contact your nearest Schneider Electric sales office.
2.
For 15 kV transformers requiring bottom entrance or exit, a separate compartment is required for adequate termination space and clearance. Transformers 1500 kVA and above with top entrance or exit may require a separate compartment to provide adequate wiring space. Contact your nearest Schneider Electric sales office, for special requirements.
3.
If transformer requires a 94-inch high enclosure for switchgear line-up, or if special enclosure is required, contact your nearest Schneider Electric sales office.
4.
For 95 kV BIL consult your nearest Schneider Electric sales office. (May affect dimensions.)

To Complete Catalog Number

Example: 1000 kVA, 3Ø, 60 Hz, 150oC temp. rise, 60 kV BIL, NEMA sound level, ventilated enclosure, 13.2 kV delta 480Y/277 = 100051H with 2-2.5% full capacity taps. 2AN and 2BN.
The correct catalog number for a 167 kVA,
2400/4160Y-120/240, 1Ø 60 Hz unit is 167S13H. The unit would be supplied with 2–2.5% above and 2–2.5% full capacity below normal taps on the primary.
Discount Schedule

navigation start Table of Contents Previous Next Index end navigtion


Release Date: 03/31/2007
Modification Date: 1/17/2008