Speed-D® Switchboards Merchandised, Service Selection Class 2710 / Refer to Pricing List 2710PL9602 Table D: I-Line® Distribution Section System Service Voltage Mains Ratings (A) DistributionInterior SCCR 240 V Max. SCCR 480 V Max. Distribution Type Indoor Outdoor Catalog No. $ Price Catalog No. $ Price 3Ø4W 208Y/120240/120480Y/277 800 I-Line 65 k 65 k Add-on distribution section, must be connected to an SB UCT and main section without distribution panel, such as SB348WS. An I-Line plug-on subfeed lug kit must be ordered to terminate the distribution section. SBAD800 6840.00 SBAD800R 8870.00 3Ø4W 208Y/120240/120480Y/277 800 I-Line 125 k 100 k Stand-alone distribution section not connected to an SB section. A back-fed main circuit breaker or I-Line plug-on subfeed lug kit must be ordered toterminate the distribution section. (Non-ULSE) SBSAD800 7080.00 SBSAD800R 9180.00 Table E: Meter Door Selection MeterSocketJaws 15-inch High Door With One MeterSocket and Test Block 30-inch High Door With Two MeterSockets and Test Blocks Catalog No. $ Price Catalog No. $ Price 6a SBA15D6MS 615.00 — 0.00 8 SBA15D8MS 656.00 — 0.00 13 SBA15D13MS 820.00 SBA30D13MS 1395.00 15 SBA15D15MS 905.00 SBA30D15MS 1478.00 Blank SBA15DBC 330.00 — 0.00 b SBA15DMS 411.00 — 0.00 a 6-jaw meter socket can also be used on 4- and 5-jaw applications. b Door with provisions for mounting meter socket. To order structure with meter door factory-installed, add door catalog number as suffix to structure (e.g. SF344IS-15D13MS). Table F: Accessories Description Catalog No. $ Price Indoor underground pull section (w/o lug landing)—26-in. (W)Order separate SA8LL lug kit below if required. SA26PS 1478.00 Outdoor (3R) underground pull section (w/o lug landing)—26 in. (W) x 24.5 in. (D)Order separate SA8LL lug landing kit below when required. SA26PSR 3039.00 Lug landing kit—800 amperes max. For terminating utility service cables in indoor or outdoor underground pull sections. SA8LLc 502.00 Single barrel lug kit —Kit provides single barrel lugs and pad in lieu of twin barrel lug provided with service section. Mechanical lugs provided are sized to fit 1-3/0–750 kcmil cable. Two lugs per phase are supplied. SA7PL 263.00 Loadside wireway—11.5 in. (W) x 14 in. (D)—indoor only SA10LW 701.00 Bus link kit—800 amperes max.—Order one kit per phase for 400, 600, and 800 A. SA10BL 164.00 Double padlock hasp attachment—For mounting two padlocks on door handle of rainproof enclosure. Padlocks not included. SS2PL 75.00 Plug-On Distribution Panel—mounts on right side of I-Line interior. Cannot be used with LA/LH branch circuit breaker. Panel rated 225 A for 240 V applications. For QO® type plug-on circuit breakers only. System Phase PoleSpaces 1Ø AC 12 SS212AC 1559.00 3Ø ABC SS312 1971.00 3Ø AB SS212ABd 1559.00 c All EUSERC Utilities (except Arizona Public Service and Salt River Project) require a lug landing kit SA8LL. d To be used on 120/240 V, 3Ø4W delta applications. Table G: Subfeed Circuit Breakers e Description Rating (A) 2-Pole f $ Price 3-Pole $ Price Catalog No. Catalog No. Left Right Left Right Subfeed Circuit Breaker Kit—Price includes circuit breaker, connectors and mounting hardware. The complete kit, mounting hardware, circuit breaker and connectors will be shipped direct from plant. Delivery is stock to three days. 100 SASFB100L( ) SASFB100R( ) 765.00 SASFB100L SASFB100R 1370.00 110 SASFB110L( ) SASFB110R( ) 765.00 SASFB110L SASFB110R 1370.00 125 SASFB125L( ) SASFB100R( ) 765.00 SASFB125L SASFB125R 1370.00 150 SASFB150L( ) SASFB150R( ) 765.00 SASFB150L SASFB150R 1370.00 175 SASFB175L( ) SASFB175R( ) 765.00 SASFB175L SASFB175R 1370.00 200 SASFB200L( ) SASFB200R( ) 765.00 SASFB200L SASFB200R 1370.00 225 SASFB225L( ) SASFB225R( ) 765.00 SASFB225L SASFB225R 1370.00 e Cannot use subfeed circuit breaker kit with multiple mains service section switchboards. f Two pole circuit breaker catalog numbers are completed by adding required phase connection letters as suffix (e.g. SASFB100LAC). Ordering Information 1. Service section: Order service section from either Table A on page 11-4 (single main circuit breaker with distribution), Table B on page 11-4 (single main fusible with distribution), or Table C on page 11-4 (multiple mains fusible), as determined by mains rating, voltage, and system. 2. Meter doors: Order meter door from Table E (meter door selection) as determined by the height and utility metering requirements. 3. Accessories and subfeeds: Order as required from Table F (accessories) and/or Table G (subfeed circuit breakers). 4. Circuit breakers and switches: Order devices from pages listed below as determined by voltage, trip rating, AIR, and mounting space. Multiple Mains and Branch Devices ● QO, QOB, QO-VH, QOB-VH: pages 7-10 and 9-10 ● I-Line: pages 9-23–9-27 ● QMB Switches: page 9-34 PE1A Discount Schedule Modified 1/17/08
Release Date: 03/31/2007Modification Date: 1/17/2008