Circuit Breakers for I-Line® Panelboards and Switchboards

 

Class 650, 651

Table 9.94:
QO® Distribution Panel—240 Vac Max. Only
Mounts in Type HCN, HCM, HCW, HCP or HCWM I-LINE panelboards, 30 A max. branch circuit breaker. Order QO plug-on circuit breakers from 9-33.
Mounting Height
Catalog Number
Catalog Number
246.
246.
246.
Table 9.95:
F-frame100 A, Thermal-magnetic (240 Vac)
Ampere
Rating
AC Magnetic
Trip Settings
Terminal
Wire
Range
 15
 20
 25
 30
 275
 275
 275
 275
 600
 600
 600
 600
 265.
 265.
 265.
#14–#4 AWG Cu or
#12–#4 AWG Al
 35
 40
 45
 50
 60
 70
 80
 90
 400
 400
 400
 400
 800
 800
 800
 900
 900
 850
 850
 850
 850
 265.
 265.
 265.
 265.
 265.
 411.
 411.
 411.
 411.
#14–#1/0 AWG Cu
or #12–#1/0 AWG Al
 15
 20
 25
 30
 275
 275
 275
 275
 600
 600
 600
 600
 381.
 381.
 381.
#14–#4 AWG Cu or
#12–#4 AWG Al
 35
 40
 45
 50
 60
 70
 80
 90
 400
 400
 400
 400
 800
 800
 800
 900
 900
 850
 850
 850
 850
 381.
 381.
 381.
 381.
 381.
 520.
 520.
 520.
 520.
#14–#1/0 AWG Cu
or #12–#1/0 AWG Al
Table 9.96:
F-frame—100 A, Thermal-magnetic (480 Vac)
Ampere
Rating
AC Magnetic
Trip Settings
Catalog Number
FY/FA Lugs
FJ/FC Lugs
 15
 20
 25
 30
 275
 275
 275
 275
 600
 600
 600
 600
AL50FA
#14-#4 AWG Cu or
#12-#4 AWG Al
AL30FD
#12–#6 AWG Al
or
#14–#6 AWG Cu
 35
 40
 45
 50
 60
 70
 80
 90
 400
 400
 400
 400
 800
 800
 800
 900
 900
 850
 850
 850
 850
 201.
 201.
 201.
 201.
 201.
 221.
 221.
 221.
 221.
  434.
  434.
  434.
  434.
  434.
  480.
AL100FA
#14–#1/0 AWG Cu or
#12–#1/0 AWG Al
AL100FD
#12–#2/0 AWG Al
or
#14–#2/0 AWG Cu
 15
 20
 25
 30
 275
 275
 275
 275
 600
 600
 600
 600
 434.
 434.
 434.
AL50FA
#14–#4 AWG Cu or
#12–#4 AWG Al
one #14–#10 AWG
 35
 40
 45
 50
 60
 70
 80
 90
 400
 400
 400
 400
 800
 800
 800
 900
 900
 850
 850
 850
 850
 434.
 434.
 434.
 434.
 434.
 555.
 555.
 555.
 555.
AL100FA
#14–#1/0 AWG Cu or
#12–#1/0 AWG Al
one #14–#3 AWG Cu
one #12–#1 AWG Al
 15
 20
 25
 30
 275
 275
 275
 275
 600
 600
 600
 600
 555.
 555.
 555.
AL50FA
#14–#4 AWG Cu or
#12–#4 AWG Al
one #14–#10 AWG
 35
 40
 45
 50
 60
 70
 80
 90
 400
 400
 400
 400
 800
 800
 800
 900
 900
 850
 850
 850
 850
 555.
 555.
 555.
 555.
 555.
 664.
 664.
 664.
 664.
AL100FA
#14–#1/0 AWG Cu or
#12–#1/0 AWG Al
one #14–#3 AWG Cu
one #12–#1 AWG Al
Table 9.97:
Example: FJA, 20 A 1-pole, 277 Vac and 70 A 2- and 3-pole QB 240 Vac.
Use phase option number for HD, HG, HJ, HL, JD, JG, JJ, JL, MG and MJ.
Phase
Option
Number