NQOB / NF Merchandised Panelboards

240 Vac and 480Y/277 Vac NQOB/NF

Class 1620, 1670 / Refer to Catalog 1670CT9601

NQOB Column-Width—240 Vac Bolt-On

NQOB Application Data

Application: For use on ac only. Meet Federal Specification W-P-115c, Type 1, Class 1. UL Listed.
Service: 1Ø3W, 3Ø3W, 3Ø4W,
3 Grd. “B’’ Ø—240 Vac max.
AIR: See tables starting on page 7-2.
Mains: Type NQOB—Bolt-on main lugs: 100 A
225 A—QB. See tables starting on page 7-2 for main circuit breaker interrupting rating.
See catalog section for terminal lug data. QD and QG main circuit breakers are also available in factory-assembled panelboards.
Branches: Bolt-on QOB, 60 A maximum.
See page 9-9 for branch circuit breaker terminal data. QOB-VH and QHB branch circuit breakers are also available as factory assembled.
Cabinet: Front—Screw cover. Box—galvanized steel with removable endwalls.
100 A—4" Min. mains end, 3" Min. opposite mains
225 A—10" Min. mains end, 5" Min. opposite mains.
Factory Assembled NQOB Column-Width Panels are available. Contact the Square D/Schneider Electric local Field Sales Office.

NQOB Column-Width—240 Vac Bolt-On

Table 9.75:
Column-Width Panelboards60 A Maximum BranchCopper Bus Standard
8.625" W. x 5" D.
for 10" WF Beams
865.
968.
828.
1293.
972.
320.
3308.
363.

NQOB Column-Width

Cable Troughs
(L=Length)a
Pull Boxes with
Solid Neutral
84
434.
96
606.
502.
653.
502.
674.

NF Column-Width—480Y/277 Vac 3Ø4W (60 A Max. Branch Circuit Breaker)

NF Application Data

Application: For use on ac only. Meet Federal Specification W-P-115c, Type 1, Class 1. UL Listed.
Service: 480Y/277 Vac, 3Ø4W
AIR: See tables starting on page 7-2
Mains: Type NF–Bolt-on main lugs: 125 A, 225 A
Main circuit breaker: 100 A—FA, 150 A—HD, 225 A—JD. See tables starting on page 7-2 for main circuit breaker interrupting rating. See catalog section for terminal lug data.
Main circuit breakers with higher interrupting ratings are available as factory assembled panelboards in the following configurations:
Table 9.77:
Mains
Rating
Circuit
Breaker
Max. No.
of Poles
HD, HG, HJ,
HL (150 A max.),
JD, JG, JJ, JL,
KI
Branches: EDB, EDG or EDJ, 60 A maximum.
See pages 6-43 and 6-44 for branch circuit breaker terminal data.
Cabinet: Front—Screw cover. Box—galvanized steel with removable endwalls.
100 A—4" Min. mains end, 3" Min.opposite mains;
225 A—10" Min. mains end, 5" Min. opposite mains.

NF Column-Width—480Y/277 Vac 3Ø4W

Table 9.78:
Column-Width—60 A Max. Branch Circuit Breaker
Max.
No.
of
Poles
Total
$ Price
(Box
Interior
and
Front)
Catalog
Number
Main Lugs Only—3 Phase 4-Wire
2186.
1839.
348.
4439.
4028.
412.

NF Column-Width

Cable Troughs
(L=Length)b
Pull Boxes with
Solid Neutral
8.625" x 5.625"
8.625" x 5.625"
84