Page 8-23
click here to download PDF version
Download PDF
Square D > On-line Catalog > Products > Operator Mechanisms and Disconnect Switches > Flange Mounted, Variable Depth Disconnect Switches: Accessories—Class 9422

navigation start Table of Contents Previous Next Index end navigtion
Square D


Digest 174 Quick Page Locator
Enter a page number from our paper catalog to go directly to that page in our online catalog.
Example: 5 - 3

Section - Page
-

Disconnect Switches

Flange Mounted, Variable Depth Disconnect Switch Accessories

Class 9422 / Refer to Catalog 9420CT9701

Remote or Dual Adaptor Kit

For the remote or dual operation of 30, 60, 100 and 200 ampere disconnect switches, or GJL, FAL, FHL, KAL, KHL, LAL, LHL, Q4L, MAL, MHL, MEL and MXL circuit breakers.

Remote Operationpermits mounting the Class 9422 Type A9 or A10 handle mechanism at a lower level than the disconnect device it controls. This arrangement is often required where the disconnect device is mounted too high for personnel to easily reach a conventional operator.

Dual Operationpermits controlling two disconnect devices, one in line with and one remote from a single Class 9422 Type A9 or A10 handle mechanism.
*
Class 9422 Type A9 or A10 (page 8-17) handle and preferred mounting method must be used.
Table 8.77:
30 A Type TCF/TCN
60 A Type TDF/TDN
100 A Type TEF/TEN
200 A Type TF
GJL
FAL, FHL
KAL, KHL
LAL, LHL, Q4L
MAL, MHL,MEL, MXL
Table 8.78:
Class 9422
Air Valve Interlock
.50 NPT
.75 NPT
342.
1.00 NPT
342.
a
Prices do not include air valves or handle mechanism. For more information on air valves listed above contact Parker at
C-PARKER@PARKER.COM, or call 1-800-272-7537.
Table 8.79:
Permits mounting Class 9422 Type A1 or A2 handle mechanisms in
enclosures with flange thickness of 16 gauge to 0.5 inch.
Auxiliary kit recommended for use with 30 and 60 A disconnect switches and
FAL, FCL, FHL, KAL KHL, NSF and NSJ circuit breaker mechanisms when
these devices are to be mounted on the center channel of a multi-door
enclosure or when extra rigidity for the flange is required. Supplied as
standard with 100 and 200 A disconnect switches and LAL, LHL, Q4L, MAL,
MHL, MEL and MXL circuit breaker mechanisms.
28.50
Auxiliary kit recommended for use with the Class 9422 Type A-1 flange
handle to facilitate padlocking the handle in the “OFF” position. Primarily
used when the handle is mounted on the center channel of a multi-door
enclosure. Also in any case where the enclosure doors interfere with the
normal padlock slot in the flange handle. Meets both the Automotive and
NFPA 79 specifications.
11.90
Special Lugs for
Disconnect Switches
Copper Lugs Only—Specify Form Y157
Tin Plated Aluminum Lugs For 400 A Type TG Switch—Specify Form Y1572
(000–750 kcmil Cu/Al wire)
Anderson Type VCEL Compression Lugs—Specify Form Y1574.
Exceptions: All 30 and 60 A disconnect switches are not available with
compression lugs.
19.10
Extra long operating rod for use with Class 9422 variable depth mechanisms.
Can be used as a substitute for the standard rod included in each kit to
increase the maximum mounting depth 7''. (Two are required for Types ARR,
RR, ART, RT, ATE, TE, ATF, TF).