Digest 174 Quick Page Locator Enter a page number from our paper catalog to go directly to that page in our online catalog. Example: 5 - 3
Disconnect Switches Flange Mounted, Variable Depth, and Cable Operated Class 9422 / Refer to Catalog 9420CT9701 The Class 9422 Type TCF, TCN, TDF, TDN, TEF, TEN disconnect switches were designed for control panel installations. These switches include common switch profile 30–100 A, interchangeable fuse clips 30–60 A, ability to add fuse clip kits and cable mechanisms. They are compatible with 9422A and 9423, and are UL recognized and CSA certified. Table 8.51: Class 9422 Flange Mounted, Variable Depth Disconnect Switches DisconnectSwitchSize VariableDepth Mtg.RangeMin.–Max.(inches) Maximum Horsepower Ratings FuseType Fuse Clip Rating(Amperes) Non-Interchangeable TypeFor Class H, J, Kor R Fuses Only Switch and OperatingMechanism Only—Does Not IncludeHandle Mechanism Switch for Use With Cable Operators ONLY—Does Not IncludeHandle Mechanism or Cable Operator Switch and Operating Mechanismand Handle Mechanism—Overpacked AC Systems Volts (Motor Volts) DC Using2 Poles250 VMaximum Includes Type A1Handle Mechanism Includes Type A2Handle Mechanism 208(200) 240(230) 480(460) 600(575) 250 V 600 V Type $ Price Type $ Price Type $ Price Type $ Price 30 A 6-5/8"–18” 7.5 7.5 15 20 5 None — — TCN30 219. TCN30C 210. ATCN301 314. ATCN302 390. H, K, J, R 30 — TCF30 248. TCF30C 239. ATCF301 342. ATCF302 419. 60 30 TCF33 266. TCF33C 257. ATCF331 362. ATCF332 440. 60 A 6-5/8"–18” 15 15 30 50 10 None — — TDN60 257. TDN60C 248. ATDN601 351. ATDN602 428. H, K, J, R 60 30 TDF60 305. TDF60C 296. ATDF601 399. ATDF602 476. — 60 TDF63 323. TDF63C 314. ATDF631 419. ATDF632 494. 100 A 6-5/8"–18” 25 30 60 75 20 None — — TEN10 380. TEN10C 371. ATEN101 476. ATEN102 551. H, K, J, R 100 100 TEF10 522. TEF10C 513. ATEF101 617. ATEF102 693. 200–400 A See 9422 TF and TG on page 8-17 Table 8.52: Internal Barrier Kits Provide an additional barrier that helps prevent accidental contact with live parts. Field installed transparent barriers do not restrict visual inspection of the switch. Barriers provide IEC529 IP2X “finger safe” protection when the door of the enclosed disconnect switch is open. A convenient door allows use of test probes without accessing fuses and replacement of fuses without removing barrier. Barrier must be used with the skirt kit to enclose a panel mounted type 9422 disconnect. Catalog Number Type ab Description Safety Switch Application (F series only) 9422 Type T Disconnect Application $ Price b SS06 Interior barrier for 60A Safety Switch, 30 or 60 A 9422 Switch 600 Vac–60 A 600 Vac–30 A 600 Vac–60 A 110. SS10 Interior barrier for 100 A Safety Switch or 100 A 9422 Switch 600 Vac–100 A 600 Vac–100 A 130. SS0306SK Skirt Kit to Enclose 30 or 60 A 9422 Switch (requires SS06) — 600 Vac–30 A 600 Vac–60 A 150. SS10SK Skirt Kit to Enclose 100 A 9422 Switch (requires SS10) — 600 Vac–100 A 170 a No Class Number is required. b For price, use Discount Schedule DE1, not CP1 Table 8.53: Class 9422 Replacement/Retrofit Fuse Clip Kits Disconnect Switch Size Switch Type Fuse Type Fuse Clip Rating(Amps) Line and Load Fuse Clip Kit (includes load base and fuse pullers) 250 V 600 V Type $ Price 30 A TCF30TCN30TCF33 H, K, J, R 30 TC30 28.50 60 30 TC33 47.60 60 A TDN60 H, K, J, R 60 30 TC33 47.60 60 TD63 66.00 Table 8.54: Class R Fuse Clip Kits Disconnect Switch Size Switch Type Fuse Type Fuse Clip Rating (AIR) Rejection Feature —Class R Kitb