Class 610
Enclosed Motor-operated Molded Case Circuit Breakers
![]()
Contact local Field Office for catalog number prior to quoting or placing an order.Motor-operated enclosed circuit breakers are utilized whenever it is desired to control the operation of an individually mounted circuit breaker from a remote location. Enclosed motor operated circuit breakers are available in either NEMA 1, 3R or 12 construction. 120 Vac control circuit required for operation of motor operator. Sufficient space is included for field-installation of a terminal block for convenient end-user control circuit wiring. Not UL Listed.
● Specify top or side mounted operator (NEMA 3R and 12 are side-mount only.)
Table 7.142: Enclosed Motor-operated Circuit Breakers FAL—240 V FAL—480 V FAL—600 V FHL—600 V KAL—600 V KHL—600 V LAL—600 V LHL—600 V MAL—600 A–600 V MAL—800 A–600 V MAL—1000 A–600 V MHL—600 A–600 V MHL—800 A–600 V MHL—1000 A–600 V
aEnclosed Walking Beam Mechanical Interlock
![]()
Contact local Field Office for catalog number prior to quoting or placing an order.Industrial molded case circuit breakers with walking beam mechanical interlocks are available in NEMA 1 and 3R construction as completely enclosed device. Walking beam mechanical interlock is available manually operated or electrically operated using (2) 120 Vac motor operators. Not UL Listed.
● Specify manually or electrically operated (electrically operated factory installed only)
Table 7.143: Enclosed Walking Beam Mechanical Interlock FAL—240 V 100 A
FAL—480 V 100 A
FAL—600 V 100 A
FHL—600 V 100 A
KAL—600 V 250 A
LAL—600 V 400 A
LHL—600 V 400 A
MAL—600 V 600 A
MAL—600 V 800 A
MAL—600 V 1000 A
MHL—600 V 600 A
MHL—600 V 800 A
MHL—600 V 1000 A
b
c Not available factory assembled. Refer to page 7-55 for merchandise enclosure.
![]()
Contact local Field Office for catalog number prior to quoting or placing an order.Ground-fault modules (GFM) can be field installed on FAL, FHL, FCL, KAL and KHL circuit breakers and enclosed in the next larger size NEMA 1 or 3R enclosure, KA and LA respectively, requires G suffix (ground fault shunt trip) circuit breaker. See page 7-47.
● Ground-fault modules are available factory installed. See table below for pricing and availability.
Table 7.144: Enclosed Circuit Breaker with Ground Fault Module Circuit Breaker
Prefix NEMA 4, 4X, 5
Stainless Steel FAL, 600 V, 15–60 A FAL, 600 V, 70–100 A