Page 7-30
click here to download PDF version
Download PDF
Square D > On-line Catalog > Products > Miniature and Molded Case Circuit Breakers > Motor Circuit Protectors: Mag-Gard® Motor Circuit Protectors (MCP)

navigation start Table of Contents Previous Next Index end navigtion
Square D


Digest 174 Quick Page Locator
Enter a page number from our paper catalog to go directly to that page in our online catalog.
Example: 5 - 3
Section - Page
-

Motor Circuit Protectors

Mag-Gard® Motor Circuit Protectors (MCP)

Class 580, 585, 680, 685

Mag-Gard® Motor Circuit Protectors (MCP) are instantaneous-trip magnetic-only circuit breakers. They have a single adjustment which simultaneously sets the magnetic trip level of each individual pole. Mag-Gard® circuit breakers comply with NEC requirements for providing motor circuit protection when installed as part of a UL Listed combination controller having motor overload protection. Interrupting ratings are established for these UL Recognized Components only when they are used in combination with motor starters with properly sized overload relays and contactors.
All Mag-Gard circuit breakers will accept the same lugs and accessories as equivalent circuit breakers. Mag-Gard circuit breakers are available with I-Line construction.c High-interruption (H) construction Mag-Gard circuit breakers (LHL and MHL) are also available.
Table 7.65:
Magnetic Only 31200 A 600 Vac, 50/60 Hza
  3
  7
 15
 30
 50
 75
9–33 A
21–77 A
45–165 A
90–330 A
150–550 A
225–825 A
726.00
726.00
726.00
726.00
920.00
1095.00
 500–1000 A
 750–1600 A
1000–2000 A
1125–2250 A
1250–2500 A
1500–3000 A
1750–3500 A
2000–4000 A
 3079.00
 3079.00
 3079.00
 3079.00
 3079.00
 3079.00
 3079.00
 600
 800
625–1250 A
 750–1500 A
1000–2000 A
1500–3000 A
2000–4000 A
2500–5000 A
3000–6000 A
3500–7000 A
4000–8000 A
4500–9000 A
 5000–10000 A
5040.00
6618.00
8470.00
J-Interrupting—600 Vac
600
1200–10000 A
800
1200–10000 A
6618.00
1500–10000 A
8470.00
1800–10000 A
11011.00
L-Interrupting—480 Vac
600
1200–10000 A
800
1200–10000 A
7009.00
1500–10000 A
8970.00
1800–10000 A
11661.00
a
250 Vdc ratings are available except on PJ and PL. No UL component recognition.
b
UL magnetic trip tolerances are -20%/+30% from the nominal values shown.
c
No GJL I-Line available.
d
Each ampere rating can be ordered with any designated trip range for the frame by adding the
proper suffix to the catalog numbers.
Discount Schedule

Related Topics
Accessories Page 7-35 and Supplemental Digest
Optional Lugs Page 7-38 and Supplemental Digest
Dimensions Pages 7-53 and 7-54

navigation start Table of Contents Previous Next Index end navigtion


Release Date: 03/31/2007
Modification Date: 3/5/2008