Digest 174 Quick Page Locator Enter a page number from our paper catalog to go directly to that page in our online catalog. Example: 5 - 3
Double Throw Safety Switch Accessories Class 3140 Table 3.45: Neutral Assembly Switch Field-Installed Standard Neutral Kit Cat. No. Terminal Data AWG/kcmil $ Price Field-Installed Copper only Neutral Kit Cat. No. Terminal Data AWG/kcmil $ Price 30–100 A Type DT, DTU (Series F) (2- and 3-pole switches only) SN0310 14–1/0 Al/Cu 76.00 SN0310C 14–1/0 Cu 80.00 30 A (Series T4) (2- and 3-pole switches only) a a 605.00 — — — 200 A Type 82000 and DTU (Series E) b a a 740.00 — — — 400 A Type 82000 DT400N (1) 4–600kcmil or(2) 1/0–250kcmil 70.00 — — — 600 A Type DTU (Series A) DT600NKD 250–500kcmil 301.00 — — — a For Type 82,000 switches, neutral is available factory-installed on 2P and 3P double throw switches. Not UL Listed. To order, add suffix N to the standard catalog number and add the above price to the list price of the switch. For DTU switches, neutral is factory-installed in standard device and is UL Listed. b Neutral assembly catalog number DT200N can be added to 4P Type 82000 switches in the field. Table 3.46: Electrical Interlocks Switch Field-Installed Electrical Interlock Kit Cat. No. c $ Price Factory-Installed $ Price Adder Per Switch 30–100 A Type DT, DTU (Series F) EIK1, EIK2 d 207.00 603.00e 200 A Type 82000 and DTU (Series E) f g — 742.00e 400 A Type 82000 EK400DTU2 173.00 — 600 A Type DTU (Series A) DS200EK2D 292.00 — c Electrical interlock kit catalog numbers with “1” suffix indicate one normally open and normally closed contact; “2” indicates two normally open and two normally closed contacts. See page 3-9 for electrical interlock ratings. d 30–100 A Type DT, DTU (Series F) switches contain (2) separate switching mechanisms. Each mechanism will accept an electrical interlock. Some applications may therefore require (2) electrical interlocks. e 30–100A Type DT, DTU (Series F) switches with factory-installed electrical interlocks installed are UL Listed and interlocks are furnished with 2 N.O. /2 N.C. contacts installed in both “ON” positions. To order, add suffix EI to standard catalog number. f Electrical interlock EK400DTU2 can be added to 4-pole Type 82000 switches in the field. g Type 82000 and DTU switches are available with electrical interlock factory-installed only. Not UL listed. Electrical interlocks are furnished with 2 N.O./N.C. contacts and are installed in both “ON” positions. To order, add suffix EI to standard switch catalog number. Table 3.47: Service Grounding Kit (Required for service equipment use.) Switch Field-Installed Service Grounding Lug Kit Cat. No. Terminal Data AWG/kcmil $ Price 30–100 A Type DT, DTU (Series F) Included Included std. 30 A Type 92,000 DT30SG (4) 14–4 Cu/Al 19.60 200 A Type 82000 and DTU (Series E) DT100SG (3) 14–1/0 Cu/Al 20.00 400 A Type 82000 PKOGTA2 (2 required) (4) 10–2/0 Cu or(4) 6–2/0 Al 36.80 600 A Type 82000 (Series A) DS468GKD 6–250kcmil 206.00 Table 3.48: Class R Fuse KitsWhen installed, this kit rejects all but Class R fuses. Kits are available for field installation. For factory installation, add “CLR” suffix to catalog number. Switch Series Number Class R Fuse Kit Cat. No. $ Price Factory-Installed $ Price Class R Fuse Kits—240 V (two kits per 3P switch) 30 A F5 RFK03 16.30 260.00 60 A F5 RFK06 17.00 260.00 100 A F5 RFK10 31.80 260.00 Class R Fuse Kits—600 V (two kits per 3P switch) 30 A F5 RFK06 17.00 260.00 60 A F5 RFK06H 17.00 260.00 100 A F5 RFK10 31.80 260.00 Key Interlock Systems For factory-installed key interlocks, refer to page 3-11. Phenolic Legend Plate For factory-installed phenolic legend plates, refer to page 3-10. Lock-On Provisions—UL Listed 30–100 A type DT, DTU (Series F) and type 92,000 included on standard device. Type 82,000 and 200 A DTU (Series E) available factory-installed. Add SPLO to catalog number and add $273. to list price. Table 3.49: Rainproof Bolt-On Hubs—For Use On NEMA 3R Enclosures Conduit Size 3/4 1 1-1/4 1-1/2 2 2-1/2 3 3-1/2 4 Closing Cap Hub Cat. No. B075 B100 B125 B150 B200 B250 B300 B350 B400 BCAP $ Price Eachh 22.20 22.20 22.20 22.20 40.90 68.00 124.00 200.00 245.00 2.50 NEMA 3R rainproof enclosures with catalog number ending in RB have a bolt-on closing cap factory-installed. Order bolt-on hubs separately from table above. For more details see page 1-13. Hubs through size 2-1/2 in. can be directly installed on RB devices. Devices requiring 3 in. or larger hubs must have holes cut in the field. Gaskets are provided on 3 in. and larger hubs. All hubs are UL Listed for indoor and rainproof applications and suitable for use with conduit having ANSI standard taper pipe thread. h See Discount Schedule. Table 3.50: Watertight Hubs—For Use On NEMA 4, 4X and 5 Stainless Steel and NEMA 12 Enclosures Conduit Trade Size 1/2 3/4 1 1-1/4 1-1/2 2 2-1/2 3 3-1/2 4 Standard-Zinc Hub Cat. No. H050 H075 H100 H125