Digest 174 Quick Page Locator Enter a page number from our paper catalog to go directly to that page in our online catalog. Example: 5 - 3
Meter Sockets Horizontal Ganged, Test Block Bypass Sockets and Accessories Class 4131 Horizontal Ganged Meter Sockets ● 1Ø, 600 Vac max., main lugs only, 2 through 6 meter positions, with and without horn or lever bypass, end or center feed, overhead and underground service feeds ● 10 kA short circuit current rating (or higher with utility approval) ● UL Listed, NEMA 3R enclosure ● Supplied with ground lugs ● Supplied with hub opening in top endwall, requires the use of a bolt-on hub, or closing plate This metering is generally utility specific. Always check with local utility company before installing. Contact your nearest Field Sales Office for additional catalog numbers, if required by utility. Table 2.2: Ringless Type, 1Ø3W, 600 Vac Max., Without Bypass or Jaw Release Branch Ratings Mains Rating (A) Cat. No. $ Price Main Lugs Phase & Neutral Al/Cu (AWG/kcmil) Branch Lugs Phase & Neutral Al/Cu (AWG) Top Endwalla Box No. See Page 2-4 Amperesc No. of Positions Socket Jaw Qty.b Service Type Hub Type (Order Separately) Closing Plate (Order Separately) 100 A 2 4 OH/UG 200 UT2R1121B 302.00 6–250 8–2/0 Series A ACP 13R 3 205 UT3R1121B 373.00 6–250 13R1 4 205 UT4R1131B 440.00 6–350 14R 5 250 UT5R1131B 605.00 6–350 15R 6 300 UT6R1131B 771.00 6–350 16R 200 A 2 4 OH/UG 205 UT2R2122B 431.00 6–250 8–250 Series A ACP 17R 4 360 UT4R2352T 737.00 1/0–500 Series A-L ACPL 18R 5 500 UT5R2392TU 922.00 1/0–500 or Series A-L ACPL 19R (2)1/0–350 6 620 UT6R2392TU 1032.00 1/0–500 or Series A-L ACPL 20R (2)1/0–350 a For Hubs and Closing Plates, see Accessories table below. b Fifth Jaw Kit available to convert 4-Jaw Socket to a 5-Jaw Socket. See Accessories table below. c Rating is continuous. Meter Mains with Test Block Bypass (Meets EUSERC Requirements) Table 2.3: Ring Type, 1Ø3W and 3Ø4W, Meter Main with Test Block Bypass (Meets EUSERC Requirements) Supplied with bondable neutral, suitable for use as service equipment. Suitable for overhead or underground service. UL Listed File E6294. System (Incoming)andService (Outgoing) MeterSocketType AmpereRating(Max.) Short CircuitCurrent Rating Cat. No.f $ Price Main Circuit Breaker Type(Order Separately)d 120/240 Vac 1Ø3W 5-Jaw 225 A 100 kA max. EMT1225CB 2730.00 2P Type QB, QD, QG, QJ, QOe, QO-VHe or QOHe 208Y/120 Vac 3Ø4Wgor240/120 Vac 3Ø4W Delta 7-Jaw 225 A 65 kA max. EMT3225CB 3570.00 3P Type QB, QD, QG or QJ d Refer to page 2-15 to select main circuit breaker. e Requires use of EZM125QOA adapter (order separately), when using QO (40 A–125 A, 2‑pole) 10kA max. SCCR, QO-VH (40 A–60 A, 2‑pole) 22kA max. SCCR, or QOH (40 A–60 A, 2‑pole) 42kA max. SCCR. Refer to page 2-15 for pricing. f Refer to page 2-4 for box dimensions. g 100 kA max. Table 2.4: EMT Terminal Wire Size h Line Phase Lug Line Neutral Lug Service Ground Lug Equipment Ground Lug Load Neutral Lug 6 AWG–300 kcmil Al/Cu 6 AWG–350 kcmil Al/Cu 4 AWG–300 kcmil Al/Cu 6 AWG–300 kcmil Al/Cu 4 AWG–300 kcmil Al/Cu h Refer to circuit breaker listings for usable load lug wire sizes. Meter Socket Accessories Table 2.5: Meter Socket Accessories Accessory Description Cat. No. $ Price Fifth Jaw Kit Converts a 4-jaw meter socket to a 5-jaw meter socket. For use on meter sockets supplied without lever bypass or jaw release only. A5J 9.90 Closing Plates(to seal hub openings) For Series A (steel) ACP 8.90 For Series A (aluminum) ACPA 7.90 For Series A-L (steel) ACPL 12.20 For Series A-L (aluminum) ACPLA 11.00 Hubs (listed by conduit size) Series A 1.00 inch A100 22.60 1.25 inch A125 22.60 1.50 inch A150 22.60 2.00 inch A200 31.90 2.50 inch A250 40.40 Series A-L 2.00 inch A200L 55.00 2.50 inch A250L 58.00 3.00 inch A300L 74.00