Digest 174 Quick Page Locator Enter a page number from our paper catalog to go directly to that page in our online catalog. Example: 5 - 3
Load Center Accessories QO® and Homeline® Accessories and Voltage testers Class 1130, 6610 / Refer to Catalog 1100CT0501 Table 1.31: QO Load Center Accessories Description Cat. No. $ Price Schedule Filler Plates Fills opening in covers if twistout is removed in error QOFP 2.40 DE3A Fills main circuit breaker opening in convertible load center covers 100–125 A QOM1FP 13.50 DE3A Fills main circuit breaker opening in convertible load center covers 150–225 A QOM2FP 13.50 DE3A Fills main circuit breaker opening in 3Ø load center covers (S01 and S02 Series) KFP 13.50 DE3A Fills main circuit breaker opening in “Q” style 3Ø load center covers (S03 Series) Q2FP 13.50 DE3A Lock Kits Use with convertible mains, 1Ø and 3Ø 100–225 A, and fixed mains, 3Ø 125–225 A indoor load centers PK6FLa 62.00 DE3A Use with 300 and 400 ampere indoor load centers PK4FL 60.00 PE1A Neutral / Ground Lugs Field-installed for 12– 2 Al or 14–4 Cu AWG wire LK70AN 6.70 DE3A Field-installed for 6–2/0 Al/Cu AWG wire LK100AN 7.20 DE3A Field-installed for 14–2/0 Al/Cu AWG wire LK125AN 14.70 DE3A Field-installed for 2–3/0 Al/Cu AWG wire LK150AN 21.60 DE3A Field-installed for 4 AWG to 300 kcmil Al/Cu wire. Use in Series S, 150–225 A QO or HOM load center LK225AN 22.10 DE3A Ground Bar Kits Standard PK15GTA with a 1–4/0 Al/Cu Lug PK15GTAL 23.30 DE3A Standard PK18GTA with a 1–4/0 Al/Cu Lug PK18GTAL 25.20 DE3A Standard PK23GTA with a 1–4/0 Al/Cu Lug PK23GTAL 27.10 DE3A Insulator Kit for PK7GTA through PK27GTA PKGTAB 29.20 DE3A Handle Padlock Attachment: For padlocking main circuit breakers in convertible load centers OFF..........50–125 A, QOM1 Frame Size QOM1PA 7.30 DE2E For padlocking main circuit breakers in convertible load centers OFF..........100–225 A, QOM2 Frame Size QOM2PA 7.30 DE2E a QO612L100DF/S, QO816L100DF/S, QO612L100DFCU/SCU, QO816L100DFCU/SCU and QO403L60NF/S DO NOT have provisions for field-installed lock. Table 1.32: Homeline Load Center Accessories Description Cat. No. $ Price Schedule Handle Padlock Attachment: For padlocking main circuit breakers in convertible load center, “OFF” 50–125 A QOM1PA 7.30 DE2E 100–225 A QOM2PA 7.30 DE2E Filler Plates Fills opening in covers if twistout is removed in error HOMFP 2.10 DE3C Fills main circuit breaker opening in convertible load centers 100–125 A QOM1FP 13.50 DE3A 150–225 A QOM2FP 13.50 DE3A Neutral Lugs Field-installed for 14–2 AWG Al or 14–4 AWG Cu wire LK70AN 6.70 DE3B Field-installed for 6–2/0 AWG Al/Cu wire LK100AN 7.20 DE3B Field-installed for 14–2/0 AWG Al/Cu wire LK125AN 14.70 DE3B Field-installed for 4 AWG–300 kcmil Al/Cu wire. Use in Series S, 150–225 A QO or HOM load center LK225AN 22.10 DE3A Miscellaneous Retaining Kit Secures circuit breaker to interior when used as a back-fed main. For HOM612L100F/S, RB and HOM48L125GC, GRB load centers. HOM1RK 4.30 DE3C Secures ONE circuit breaker right side of interior when used as a back-fed main. For 100–125 A convertible main load centers, Series S01 and S02 HOM4RK2LA 9.80 DE3C Secures ONE circuit breaker right side of interior when used as a back-fed main. For 150–225 A convertible main load centers, Series S01 and S02 HOM4RK2HA 9.80 DE3C Secures circuit breaker to interior when used as a back-fed main.For 2P 150–200 A circuit breakers HOM5RK 9.80 DE3C Lock Kit Use with convertible indoor load center covers (Series S-1) PK6FL 62.00 DE3A Replacement Cover Directory Label 1 through 42 numbered universal replacement directory label for load center covers LSDL .36 DE5 Circuit Identification Stickers: Circuit identification stickers for use on cover directory labels to identify branch circuits PSDS .50 DE5 Generator Circuit Breaker Interlock Kit For use on “S” Series NEMA 1 and “S1” and “S2” Series NEMA 3R load centers. Interlocks a QOM1 2P maincircuit breaker of a load center (100–125 A) with a Homeline 2P (15–125 A) branch circuit breaker. HOMCRBGK1 70.00 DE3D For use on “S” Series NEMA 1 and “S1” Series NEMA 3R load centers. Interlocks a QOM2 2P main circuit breaker of a load center (150–225 A) with a Homeline 2P (15–125 A) branch circuit breaker. HOMCGK2 70.00 DE3D For use on “S2” Series NEMA 3R load centers. Interlocks a QOM2 2P main circuit breaker of a load center (150–225 A) with a Homeline 2P (15–125 A) branch circuit breaker. HOMRBGK2 70.00 DE3D Table 1.33: Voltage TestersSolenoid Type with polarity indication and slotted receptacles for holding prods. UL and CSA Listed. Description Type $ Price Schedule The Voltage Tester 120-240-480-600 Vac 50/60 Hz; 120-240-600 Vdc 6610VT1 67.00 DE3B Same as VT-1 except with fused leads 6610VT1S 74.00 DE3B Deluxe Simulated Leather Carrying Case 6610L2 39.30 DE3B Replacement Polarity Indication Cap b 6610PC1 8.00 DE3B Replacement Leads b 6610P1 25.70 DE3B Fused Replacement Leads b 6610P1S 35.50 DE3B b IMPORTANT: Will fit only Class 6610 Series A testers and Catalog Number 5008, Series B testers. Will not fit 5008 Pre-Series B testers. Leads must be replaced as a unit. Replacement of individual lead components must not be attempted.