Mechanical Latch Attachment—Mounts on any 2 through 8-pole relay (except XMO master relay). The Type XL and XDL latch attachments are identical in size and mounting provisions. The Type XLAC latch attachment has a continuous-duty-rated coil which is replaceable. The Type XDLDC latch attachment has an intermittent–rated coil (replaceable) and should be connected through a N.O. contact of the basic relay if the input signal is maintained to the unlatch coil. AC Latch Attachment
DC Latch Attachment
|
XDLa
| $134.00 176.00
| |||
| Pneumatic Timer Attachment—Mounts on any 0 through 4-pole AC or DC relay (except XMO master relay). It provides 1 N.O. and 1 N.C. convertible timed contacts, which are the same Type XC1 cartridges used on the basic relay. Two timing ranges are available, and conversion from On Delay to Off Delay or vice versa is easy. Off Delay
0.2–60 seconds
5–180 seconds
On Delay
0.2–60 seconds
5–180 seconds
|
| 266.00
266.00
266.00
266.00
| ||
| | Timer Lockout Cover—Fits over the time delay adjustment knob of any Type XT timing attachment. The Lockout Cover is designed to protect the time setting against accidental adjustment. It mounts directly to the timing attachment with two included screws. |
7.10
| |||
|
Adder Decks—Adder decks are used to expand the number of poles on a relay. The basic 4-pole relay can be easily converted to an 8-pole or 12-pole relay by installing one or two adder decks. The Class 8501 Type XB20 comes with 2 convertible contact cartridges and will accept 2 additional convertible contact cartridges. The Class 8501 Type XB40 comes with 4 convertible contact cartridges. The same Type XB adder deck is used for both the middle and upper decks of the AC or DC relay. With 2 N.O. contact cartridges
With 4 N.O. contact cartridges
|
38.00
77.00
| |||
Logic Reed Adder Deck—Used for switching low energy circuits. The Logic Reed Adder Deck is supplied with either one or two logic reed cartridges fixed into the center positions of an adder deck. Contact cartridges are neither convertible nor replaceable. Standard cartridges can be inserted in unused cavities of the Logic Reed Adder Deck. One or two Logic Reed Adder Decks may be added to the basic 4-pole relay. See Contact Rating Data on pages 21-5 and 21-6 for electrical ratings. | Number of N.O.
Logic Reed
Contact Cartridges
2
1
1
0
0
| Number of N.C.
Logic Reed
Contact Cartridges
0
1
0
1
2
| 105.00
105.00
52.20
52.20
105.00
| ||
|
Contact Cartridges—The Type X relay offers 4 Types of contact cartridges. All are color–coded for visual identification of each Type.
|
||||
Standard Cartridge—The standard cartridge, used for most applications, has a black case.
|
19.10
| ||||
Overlapping Cartridge—Same NEMA Type A600 AC rating as standard cartridge and a NEMA Type P150 DC rating. When it is used in the N.O. mode it will close early and when used in the N.C. mode it will open late. If two or more are used together, the N.O. contacts will close before the N.C. contacts open as the relay picks up. Overlap also occurs during dropout. Overlapping cartridge has a red case. |
19.10
| ||||
May be ordered factory installed:
Substitute 1 N.O. and 1 N.C. overlapping cartridges for 2 standard cartridges.
Substitute 2 N.O. and 2 N.C. overlapping cartridges for 4 standard cartridges.
Substitute 3 N.O. and 3 N.C. overlapping cartridges for 6 standard cartridges.
Substitute 4 N.O. and 4 N.C. overlapping cartridges for 8 standard cartridges.
|
Form
Y1591
Y1592
Y1593
Y1594
| Add 19.10
Add 19.10
Add 19.10
Add 19.10
| |||
Master Cartridge—Features the same contact ratings as the Type XC1 standard cartridge except it has a 20 ampere continuous current rating instead of 10 amperes. It can be used in circuits where a master relay is required. Master cartridge has a blue case. Maximum of 6 master cartridges may be used on any 7 and 8-pole AC relays. Do not use any master cartridges on 9-12-pole AC or any DC-operated devices. Note: If master cartridges are added to a standard relay, attachments (latch mechanism, timers, etc.) cannot be used. |
47.60
| ||||
Logic Reed Cartridge—See logic reed adder deck above.
|
|||||
| Mounting Track—The mounting track has pre-punched mounting holes to simplify mounting the track on the control panel. The relay mounting screws are factory installed on the track so that the relays can be hung prior to tightening the screws. 9'' long for 4 relays
18'' long for 8 relays
27'' long for 12 relays
36'' long for 16 relays
72'' long for 32 relays
|
15.60
23.60
28.80
33.90
60.00
| |||
|
Manual Test Tool—Provides a means of manually switching the contacts of a basic relay or timing relay and holding all contacts in their switched state until the tool is removed. This simplifies the checking of control circuits without power on the coil or contacts. |
4.80
| |||
Transient Suppressor—Consists of an R-C circuit designed to suppress coil generated transients to approximately 200 percent of peak voltage. It is particularly useful when switching the Type X relay near solid state equipment. It is designed for use on coils up to 120 Vac. |
38.00
| ||||
| NEMA Type 1 Enclosure—Formed from sheet steel to provide strength and rigidity. Two conduit knockouts are located in both the top and bottom of the enclosure. The enclosure is furnished with self tapping screws for mounting the relay inside the enclosure. Accommodates a single 4 or 8-pole AC or DC relay, 12-pole AC relay, 4-pole AC latching relay, and 4-pole AC timing relay. NOTE: The 4-pole DC latching relay, 4-pole DC timing relay, 8-pole AC and DC latching relays and 12-pole utility auxiliary relay will not fit. |
Class
9991
Type
| 66.00
| ||
Device
Type
|
Equipment To Be Serviced
|
Coil
Prefix
or Class
and Type
|
Hz
|
SUFFIX NUMBER
(Complete Coil Number Consists of Prefix or Class and Type Followed by Suffix Number.)
|
Coil
Burden
Watts
|
Price
|
|||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Class
|
Type
|
6
Volts
|
12
Volts
|
18
Volts
|
24
Volts
|
32
Volts
|
48
Volts
|
64
Volts
|
72
Volts
|
90
Volts
|
110
Volts
|
115/
125
Volts
|
220
Volts
|
230/
250
Volts
|
|||||
DC
|
8501
|
XD
| 9998 XD
| 19
| 28
| 34
| 37
| 40
| 46
| 49
| 52
| 55
| . . .
| 58
| . . .
| 67
| 18
| $122.00
| |
XDL
| 9998 XDL
| 19
| 28
| 34B
| 37B
| 40B
| 46B
| 49B
| 52B
| 55B
| . . .
| 58B
| . . .
| 67B
| 50
| 156.00
| |||
XUD
| 9998 XUD
| 19
| 28
| . . .
| 37
| . . .
| 46
| . . .
| . . .
| . . .
| . . .
| 58d
| . . .
| 67c
| 16
| 122.00
| |||
Device
Type
|
Equipment To Be Serviced
|
Coil
Prefix
or Class
and Type
|
Coil Volt-Amperes
|
||||||||||||||||
Class
| Type
| 24
Volts
| 110-
115
Volts
| 120
Volts
| 208
Volts
| 220
Volts
| 240
Volts
| 277
Volts
| 380
Volts
| 440
Volts
| 480
Volts
| 550
Volts
| 600
Volts
| In-
rush
| Sealed
| ||||
AC
|
8501
|
XO,
XMO
|
9998 X b
|
60
| 23
| . . .
| 44
| 51
| 52
| 53
| 55
| . . .
| . . .
| 62
| . . .
| 65
| 148
| 23
| 49.80
|
50
| 24
| 44
| . . .
| 52
| 53
| . . .
| . . .
| . . .
| 62
| . . .
| 65
| . . .
| 143
| 25
| |||||
For additional information, reference Catalog #8501CT9601.