Environment
Degree of protection
|
Conforming to IEC 529
| IP65, unless otherwise stated
IP66, for booted push button heads
|
Conforming to UL 50 and CSA C22.2 No. 94
| Type 1, 2, 3, 4, 4X, 12, and 13, unless otherwise stated
|
Conforming to standards
| | IEC 947-1, IEC/EN 60947-5-1, IEC 947-5-4,
EN 60947-1, JIS C 4520,
UL 508, CSA C22.2 No. 14
|
Product certifications
|
UL Listed, CSA
| Standard single contacts with screw clamp terminals: A600; Q600
Double contacts with screw clamp terminals: A600; Q600
Light modules with screw clamp terminals
JOYSTICK XD4-PA: A600; R300
|
BV, RINA, LROS, DNV, GL (pending)
| Standard single contacts and double contacts with screw clamp terminals
|
Electrical Characteristics of Operators and Contact Blocks |
Cabling capacity
| Conforming to IEC 947-1
| Screw and captive clamp terminals
Min: 1 x 24 AWG (0.22 mm2) without cable end
1 x 22 AWG (0.34 mm2) for linking
Max: 2 x 16 AWG (1.5 mm2) with cable end
2 x 14 AWG (2.5 mm2) without cable ends
Cross headed screw (POZIDRIV type 1) slotted for flat 4 and 5.5 mm screwdriver
|
Maximum Contact Block
Usage
|
XB4/ZB4 Maximum Number of Blocks
|
Push buttons (Non-Illuminated)
|
9
|
Selector switches (Non-Illuminated)
|
6
|
Push buttons and selectors (Illuminated)
|
6
|
Mushrooms, Push Pull (Non-Illuminated)
|
6
|
Mushrooms, Push Pull (Illuminated)
|
4
|
Mushrooms, Turn-to-Release (Non-Illuminated)
|
6
|
Mushrooms, Trigger Action (Non-Illuminated)
|
4
|
Push-on/Push-off (Non-Illuminated)
|
3
|
Push-on/Push-off (Illuminated)
|
2
|
Rated operational
characteristics
Conforming to
IEC/EN 60947-5-1
|
AC supply:
Utilization category AC-15
| Standard blocks (single or double) with screw clamp terminals:
A600: Ue = 600 Vac and le = 1.2 A or Ue = 240 Vac and le = 3 A
or Ue = 120 Vac and le = 6 A
Continuous Thermal Current: 10 A
|
DC supply:
Utilization category DC-13
| Standard single or double blocks with screw clamp terminals:
Q600: Ue = 600 Vdc and le = 0.1 A or Ue = 250 Vdc and Ie = 0.27 A
or Ue = 125 Vdc and le = 0.55 A
Joystick XD4-PA:
R300: Ue = 125 Vdc and le = 0.22 A or Ue = 250 Vdc and le = 0.1 A
|
Electrical durability
Conforming to
IEC/EN 60947-5-1
Appendix C
Operating rate
3600 operating cycles/hour.
Load factor: 0.5
|
AC supply for 1 million operating cycles,
utilization category AC-15
|
Standard blocks for screw clamp terminals:
|
24 Vac
| 120 Vac
| 230 Vac
|
4 A
| 3 A
| 2 A
|
Standard double blocks with screw clamp terminals:
|
24 Vac
| 120 Vac
| 230 Vac
|
3 A
| 1.5 A
| 1 A
|
DC supply for 1 million operating cycles,
utilization category DC-13
|
Standard single blocks for screw clamp terminals:
|
24 Vdc
| 110 Vdc
|
0.5 A
| 0.2 A
|
Standard double blocks with screw clamp terminals:
|
24 Vdc
| 110 Vdc
|
0.4 A
| 0.15 A
|
Electrical Characteristics of Light Modules |
Cabling capacity
| Conforming to IEC 947-1
| Screw and captive clamp terminals
Min: 1 x 24 AWG (0.22 mm2) without cable end
1 x 22 AWG (0.34 mm2) for linking
Max: 2 x 16 AWG (1.5 mm2) with cable end
|
Specific Characteristics of Protected LED® Light Modules Only |
Voltage limits
| Nominal voltage
| 24 V: 19.2 to 30 Vdc, 21.6 to 26.4 Vac; 120 V: 102 to 132 Vac; 240 V: 195 to 264 Vac
|
Current consumption
| Applicable to all colors
| 24 Vac/dc supply blocks: 18 mA
120 Vac supply blocks: 14 mA
240 Vac supply blocks: 14 mA
|