Schneider Electric Brands
Page 14-89
click here to download PDF version
Download PDF

Search     
Table of Contents Previous Page Next Page Product Index


WELL-GUARD® Pump Panel

Reduced Voltage Type Class 8940

Class 8940 Reduced Voltage panels in NEMA 3R enclosures are specifically designed for pumping applications. Extra space is provided for field installation of auxiliary equipment.

Type S contactors/starters provided as standard
All devices are UL Listed, and marked "SUITABLE ONLY FOR USE AS SERVICE EQUIPMENT"
Price includes Hand-Off-Auto selector switch and Start push button

Closed Transition Autotransformer Type
3-Pole Polyphase—480 Vac Maximum (50–60 Hz)

Note that the prices shown do not include thermal units. Devices require 3 thermal units (Sizes 2–6). Standard trip thermal units are $14.30 each. See page 14-129 for selection information.

Motor
(Starter)
Volts
Max.
Hp
Polyphase
Coil
Voltage
NEMA
Size
Fusible Disconnect Type
Circuit Breaker Type
Fuse
Clip
Amperes
a
Type
Price
Circuit
Breaker
Type
Price
230
(240)  
 15  
240–60
220–50  
2b  
 60  
RD4DV03c
$ 7952.  
FAL36080  
VD1DV03c
$ 7952.  
 25  
3b  
100  
RE4FV03c
11370.  
FAL36100  
VE1FV03c
11370.  
 30  
200  
RE1GV03c
11561.  
KAL36100  
VE2GV03c
11561.  
 50  
4b  
200  
RF4JV03c
17771.  
KAL36200  
VF1JV03c
18738.  
 75  
5b  
400  
RG1LV03c
29297.  
LAL36250  
VG2LV03c
29297.  
100  
400  
RG1MV03c
30722.  
LAL36350  
VG2MV03c
30722.  
460
(480)  
 25  
480–60
440–50  
2b  
 60  
RD2FV06c
8370.  
FAL36070  
VD1FV06c
8370.  
 30  
3b  
100  
RE2GV06c
11390.  
FAL36080  
VE1GV06c
11390.  
 50  
100  
RE2JV06c
12131.  
FAL36100  
VE1JV06c
12131.  
 75  
4b  
200  
RF2LV06c
17771.  
KAL36125  
VF1LV06c
18581.  
100  
200  
RF2MV06c
18852.  
KAL36200  
VF1MV06c
18852.  
150  
5b  
400  
RG3PV06c
28490.  
KAL36250  
VG4PV06c
30893.  
200  
400  
RG3QV06c
32573.  
LAL36350  
VG4QV06c
34158.  
300  
6b  
...  
...  
...  
MAL36600  
VH1SV06c
52892.  
400  
...  
...  
...  
MAL36900  
VH2TV06c
52892.  
600  
7b  
...  
...  
...  
MAL361000  
VJ1WV06c
82089.  

a Fuse clips are sized for use with dual-element time-delay fuses.
b Overload relays are ambient temperature compensated.
c Coil voltage code must be specified to order this product. Refer to standard voltage codes shown to the left.

Part Winding Type
3-Pole Polyphase—480 Vac Maximum (50–60 Hz)

Note that prices shown do not include thermal units. Devices require 6 thermal units (Sizes 2–6). Standard trip thermal units are $14.30 each. See page 14-129 for selection information.

Motor
(Starter)
Voltage
Max.
Hp
Polyphase
Coil
Voltage
NEMA
Size
Combination Fusible
Disconnect Type
Combination Circuit Breaker Type
Fuse
Clip
(2 Sets)
(A)
d
Type
Price
Circuit
Breaker
(2 Bkrs.)
Frame
Size
Type
Price
230
(240)  
 25  
240–60
220–50  
2PWe  
 60  
MD4FV03f
$ 5024.  
FAL36070  
PD1FV03f
$ 4862.  
 30  
3PWe  
 60  
ME5GV03f
7739.  
FAL36080  
PE3GV03f
7548.  
 50  
100  
ME6JV03f
7739.  
FAL36100  
PE3JV03f
7548.  
 75  
4PWe  
200  
MF1LV03f
14547.  
KAL36150  
PF3LV03f
15600.  
100  
5PWe  
200  
MG3MV03f
28884.  
KAL36175  
PG2MV03f
28884.  
125  
400  
MG1NV03f
28884.  
LAL36250  
PG3NV03f
28884.  
150  
400  
MG1PV03f
28884.  
LAL36250  
PG3PV03f
28884.  
460
(480)  
 30  
480–60
440–50  
2PWe  
 30  
MD5GV06f
5024.  
FAL36040  
PD1GV06f
4862.  
 40  
 60  
MD2HV06f
5024.  
FAL36050  
PD1HV06f
4862.  
 60  
3PWe  
 60  
ME7KV06f
7739.  
FAL36070  
PE3KV06f
7548.  
 75  
100  
ME3LV06f
7739.  
FAL36090  
PE3LV06f
7548.  
100  
4PWe  
200  
MF3MV06f
15600.  
FAL36100  
PF2MV06f
15600.  
150  
200  
MF3PV06f
15600.  
KAL36125  
PF3PV06f
15600.  
200  
5PWe  
200  
MG4QV06f
28884.  
KAL36175  
PG2QV06f
28884.  
250  
200  
MG4RV06f
28884.  
KAL36225  
PG3RV06f
28884.  
350  
400  
MG2TV06f
28884.  
LAL36300  
PG3TV06f
28884.  

d Fuse clips are sized for use with dual-element time-delay fuses.
e Overload relays are ambient temperature compensated.
f Coil voltage code must be specified to order this product. Refer to standard voltage codes shown above to the left.

Coil Voltage Codes
Voltage
Code
Price Adder
60 Hz
50 Hz
24hg
120h
208
240
...
480
600
Specify  
...
110
...
220
380
440
550
Specify  
V01
V02
V08
V03
V05
V06
V07
V99  
N.C
N.C
N.C
N.C
N.C
N.C
N.C
$23.70  

g 24 V coils are not available on Sizes 4–7. On Sizes 2–3, where 24 V coils are available, Form S (separate control) must be specified.
h These voltage codes must include Form S (no charge).

For additional information, reference Catalog #8940CT9701.



CP1

          

Discount
Schedule

3/12/04 © 2005 Schneider Electric
All Rights Reserved
 
Table of Contents Previous Page Next Page Product Index